Electrical Tomography: a review of Configurations and Applications to Particulate Processes
Despite decades of research, the study of suspension flows still continues to be a subject of great scientific interest. In the development of accurate models for suspension-related processes, prior knowledge of ...
Maria G. Rasteiro +3 more
doaj +1 more source
Electrical Impedance Tomography (EIT) is a clinically used tool for bed-side monitoring of ventilation. Previous work also showed a high potential for lung perfusion monitoring with indicator-enhanced EIT.
Augustin Xenia +5 more
doaj +1 more source
Probing deep lung regions using a new 6-electrode tetrapolar impedance method
Probing deep regions of the lung using electrical impedance is very important considering the need for a low cost and simple technique, particularly for the low and medium income countries.
Mobarak Mahjabin +2 more
doaj +1 more source
Relativistic liquids: GENERIC or EIT?
Abstract We study the GENERIC hydrodynamic theory for relativistic liquids formulated by Öttinger and collaborators. We use the maximum entropy principle to derive its conditions for linear stability (in an arbitrary reference frame) and for relativistic causality.
L Gavassino, M Antonelli
openaire +4 more sources
Quality of Service (QoS) improving schemes in optical networks
In optical networks, such as OPS/OBS, the network results into significant loss in the network layer. When the loss significantly deteriorates the QoS by increasing the Bit Error Rate (BER), a viable approach can be used to increase the performance. This
Dawit Hadush Hailu +3 more
doaj +1 more source
Mathematical lung model for local gas exchange based on EIT-measurements
In this work we present a four compartment mathematical lung model to simulate the local gas exchange based on electrical impedance tomography (EIT) input.
Hennigs Carlotta +2 more
doaj +1 more source
Mechanical and water-absorption properties of composites made from sisal fiber and polyester matrix have been investigated. Test specimens were prepared with untreated fiber and treated with alkaline solution of sodium hydroxide.
Agernew Melkamu +2 more
doaj +1 more source
Design of a miniaturized wearable EIT system for imaging and hand gesture recognition
Hand gesture recognition using data from electrical impedance tomography (EIT) systems offers many promising applications, for example in the field of human-computer interaction. Due to its real-time capability and the use of harmless currents for humans,
Liebing Tom +2 more
doaj +1 more source
Image reconstruction in EIT is an inverse problem, which is ill posed and hence needs regularization. Regularization brings stability to reconstructed EIT image with respect to noise in the measured data.
Ranade Nanda V., Gharpure Damayanti C.
doaj +1 more source
Evaluation of EIT system performance [PDF]
An electrical impedance tomography (EIT) system images internal conductivity from surface electrical stimulation and measurement. Such systems necessarily comprise multiple design choices from cables and hardware design to calibration and image reconstruction.
Mamatjan, Yasin +3 more
openaire +2 more sources