Results 61 to 70 of about 1,230,105 (298)
Comparison of lung aeration loss in open abdominal oncologic surgeries after ventilation with electrical impedance tomography-guided PEEP versus conventional PEEP: a pilot feasibility study [PDF]
Background Existing literature lacks high-quality evidence regarding the ideal intraoperative positive end-expiratory pressure (PEEP) to minimize postoperative pulmonary complications (PPCs). We hypothesized that applying individualized PEEP derived from
A. R. Karthik +9 more
doaj +1 more source
The dielectric‐coated impedance cylinder configuration is investigated thoroughly with respect to the space‐wave, leaky‐wave and creeping‐wave excitations for all source polarizations.
Mahesh Singh +2 more
doaj +1 more source
Single‐cell DNA methylation (scDNAme) profiling maps epimutational clonal evolution, revealing mechanisms of malignancy and therapeutic resistance across diverse cancer types. By providing a high‐resolution landscape of intratumoral heterogeneity, these technologies empower precise patient stratification, guide the development of enhanced ...
Ik Soo Kim
wiley +1 more source
Arcing High Impedance Fault Detection Using Real Coded Genetic Algorithm
Safety and reliability are two of the most important aspects of electric power supply systems. Sensitivity and robustness to detect and isolate faults can influence the safety and reliability of such systems.
Zamanan, N. +2 more
core +1 more source
Impedance assessment in living biological cells has gained popularity as a label-free, real-time, and quantitative analytical approach for determining cellular states.
Hassan Moghtaderi +6 more
doaj +1 more source
Electrical Impedance of Isolated Amnion
The electrical impedance of the guinea pig amniotic membrane was measured, under standardized conditions, over the frequency range of 20 to 7000 cycles/second. This impedance can be represented analytically by a simple frequency-dependent function which is precisely of the form of the Debye relaxation equation.
Silver, Gordon A. +2 more
openaire +2 more sources
TRANSVERSE ELECTRIC IMPEDANCE OF NITELLA [PDF]
Alternating current measurements have been taken on single Nitella cells over a frequency range from 30 to 2,500,000 cycles per second with the current flow perpendicular to the axis of the cell. The measuring cells were so constructed that electrolytes of any desired concentration could be circulated during the course of the measurements.
H J, Curtis, K S, Cole
openaire +2 more sources
Optimal transportation for electrical impedance tomography
This work establishes a framework for solving inverse boundary problems with the geodesic-based quadratic Wasserstein distance ( W 2
Gang Bao, Yixuan Zhang
openaire +4 more sources
Functional screening identified PcSyn14890, a cyanobacteria‐specific protein that enhances growth and stress resistance in E. coli and Synechocystis PCC6803. Although we expected it to function as a molecular chaperone, it was unable to protect against thermal aggregation of GAPDH.
Akiyo Yamada +7 more
wiley +1 more source
Functional Electrical Impedance Tomography of adult and neonatal brain function. [PDF]
Electrical Impedance Tomography (EIT) is a fast, portable imaging technique that produces tomographic images of the internal impedance of an object from surface electrode measurements.
Tidswell, A.T. +1 more
core

