Otology & Neurotology, 2008
Cochlear implantation is a common treatment approach for children with auditory neuropathy/dyssynchrony (AN/AD) who do not benefit from hearing aids. The auditory brainstem response (ABR) is a measure of neural synchrony along the auditory pathway up through the brainstem.
Christina L, Runge-Samuelson +2 more
openaire +2 more sources
Cochlear implantation is a common treatment approach for children with auditory neuropathy/dyssynchrony (AN/AD) who do not benefit from hearing aids. The auditory brainstem response (ABR) is a measure of neural synchrony along the auditory pathway up through the brainstem.
Christina L, Runge-Samuelson +2 more
openaire +2 more sources
Electrocochleography and Auditory Brainstem Electric Responses in Patients with Pontine Angle Tumors
Annals of Otology, Rhinology & Laryngology, 1980In 45 patients with surgically proven pontine angle tumors, compound action potential (AP) and summating potential (SP) were recorded with transtympanic electrocochleography (ECochG) together with brainstem electric responses (BSER). The aims were to quantify the mechanism by which tumors cause hearing loss and to evaluate the diagnostic potentials of
J J, Eggermont, M, Don, D E, Brackmann
openaire +2 more sources
Hearing Research, 2007
The purpose of this study was to distinguish the effects of different parameters on latencies of wave IIIe, wave Ve, and interpeak interval IIIe-Ve of electrical auditory brainstem responses (EABRs). EABRs were recorded from all the intra-cochlear electrodes in eight adult HiRes90K((R)) cochlear implant users.
Jeanne, Guiraud +5 more
openaire +2 more sources
The purpose of this study was to distinguish the effects of different parameters on latencies of wave IIIe, wave Ve, and interpeak interval IIIe-Ve of electrical auditory brainstem responses (EABRs). EABRs were recorded from all the intra-cochlear electrodes in eight adult HiRes90K((R)) cochlear implant users.
Jeanne, Guiraud +5 more
openaire +2 more sources
2006
The number of electrodes that elicit usable auditory sensations with an auditory brainstem implant varies significantly between subjects. For those with only very few, movement of the array by only a few millimetres could make a significant improvement to their outcome, but yet the point at which this is normally discovered is during activation, weeks ...
openaire +2 more sources
The number of electrodes that elicit usable auditory sensations with an auditory brainstem implant varies significantly between subjects. For those with only very few, movement of the array by only a few millimetres could make a significant improvement to their outcome, but yet the point at which this is normally discovered is during activation, weeks ...
openaire +2 more sources
Reduction of stimulation coherent artifacts in electrically evoked auditory brainstem responses
Biomedical Signal Processing and Control, 2015Abstract The electrically evoked auditory brainstem response (eABR) is one of the clinically employed objective evaluation tools for cochlear implant (CI) subjects. It is commonly obtained by averaging responses, but because of the electric CI stimulation, some artifacts are phase locked to the stimulus and do not average out by increasing ...
Hongmei Hu +2 more
openaire +1 more source
Characterization of the electrically evoked auditory brainstem response (ABR) in cats and humans
Hearing Research, 1986Electrically evoked auditory brainstem response (EABR) recordings were made from 38 humans implanted with one of three cochlear prostheses, and from 25 cats. Recognizable auditory potentials were identified in 27 of the profoundly deaf implanted subjects.
C, van den Honert, P H, Stypulkowski
openaire +2 more sources
Measurement of auditory brainstem responses evoked by electrical stimulation with a cochlear implant
British Journal of Audiology, 1990Auditory brainstem responses evoked by electrical stimulation with a Nucleus/Cochlear implant can be measured if care is taken to prevent stimulus artefacts. A simple procedure is described which relies upon a passive LCR filter to prevent the radiofrequency carrier from entering the input of the recording amplifier.
C J, Game, D R, Thomson, W P, Gibson
openaire +2 more sources
Electrically evoked auditory brainstem response to stimulation of different sites in the cochlea
Hearing Research, 1993It is often assumed that stimulation of the eighth nerve with brief current pulses results in a highly synchronous discharge of action potentials from the ensemble of excited nerve fibers. Latency data derived from the electrically evoked auditory brainstem response (EABR) of the guinea pig and human indicate that there is a baso-apical gradient of ...
C A, Miller, P J, Abbas, C J, Brown
openaire +2 more sources
Pre-perioperative, transtympanic electrically evoked auditory brainstem response in children.
International journal of audiology, 2005The purpose of this study was to characterize the transtympanically evoked, perioperative electrically evoked auditory brainstem response (EABR) and define its relationship with preoperative hearing, age and hearing loss etiology in 59 children (10-60 months of age) who had received cochlear implants.
Paul R, Kileny, Teresa A, Zwolan
openaire +1 more source
Prediction of auditory nerve survival in humans using the electrical auditory brainstem response.
The American journal of otology, 1992This investigation studied the electrical auditory brainstem response (EABR) input-output functions in three groups of patients: individuals with normal auditory neural systems; patients with acquired, profound sensorineural hearing loss; and patients with congenital, profound sensorineural hearing loss.
R C, Fifer, M A, Novak
openaire +1 more source