Results 21 to 30 of about 1,582,459 (236)
Electrical properties of a-antimony selenide
This paper reports conduction mechanism in a-\sbse over a wide range of temperature (238K to 338K) and frequency (5Hz to 100kHz). The d.c. conductivity measured as a function of temperature shows semiconducting behaviour with activation energy $\Delta$E=
A C Adams+24 more
core +1 more source
Carbon nanotubes and silver flakes filled epoxy resin for new hybrid conductive adhesives [PDF]
Combining conductive micro and nanofillers is a new way to improve electrical conductivity. Micrometric silver flakes and nanometric carbon nanotubes (CNTs) exhibit high electrical conductivity.
Courtade, Frédéric+7 more
core +1 more source
The impact of frailty syndrome on skeletal muscle histology: preventive effects of exercise
Frailty syndrome exacerbates skeletal muscle degeneration via increased ECM deposition and myofiber loss. This study, using a murine model, demonstrates that endurance exercise attenuates these histopathological alterations, preserving muscle integrity. Findings support exercise as a viable strategy to counteract frailty‐induced musculoskeletal decline
Fujue Ji+3 more
wiley +1 more source
Dielectric mixtures -- electrical properties and modeling
In this paper, a review on dielectric mixtures and the importance of the numerical simulations of dielectric mixtures are presented. It stresses on the interfacial polarization observed in mixtures.
Gubanski, Stanislaw M.+2 more
core +1 more source
Electrical Transport Properties of Single-Layer WS2 [PDF]
We report on the fabrication of field-effect transistors based on single and bilayers of the semiconductor WS2 and the investigation of their electronic transport properties.
Allain, Adrien+4 more
core +2 more sources
Abstract The establishment of guidelines and curriculum standards for medical physics residency training is a critical component of setting expectations and competencies for the profession. Since the last publication of these standards, residency training has become integrated into the eligibility criteria for most medical physics certification bodies.
Jonathon A. Nye+16 more
wiley +1 more source
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa+4 more
wiley +1 more source
Electrical noise properties in aging materials
The electric thermal noise has been measured in two aging materials, a colloidal suspension (Laponite) and a polymer (polycarbonate), presenting very slow relaxation towards equilibrium.
Bellon, L.+3 more
core +4 more sources
Cerebral Amyloid Angiopathy Is Associated With Higher R2 Relaxation Rate: An MRI and Pathology Study
ABSTRACT Objective Cerebral amyloid angiopathy (CAA) involves β‐amyloid deposition in the walls of cortical and leptomeningeal small vessels. Transverse relaxation rate (R2) is a major source of contrast in MRI. This study tested the hypothesis that CAA is associated with R2, extracted the spatial pattern of CAA‐related R2 abnormalities, and evaluated ...
Md Tahmid Yasar+6 more
wiley +1 more source
Self-Heating Ability of Geopolymers Enhanced by Carbon Black Admixtures at Different Voltage Loads [PDF]
Sustainable development in the construction industry can be achieved by the design of multifunctional materials with good mechanical properties, durability, and reasonable environmental impacts.
Fiala L.+4 more
core +1 more source