Results 91 to 100 of about 58,890 (209)
Large-Stroke Dielectric Elastomer Actuators With Ion- Implanted Electrodes [PDF]
In this paper, we present miniaturized polydimethyl- siloxane (PDMS)-based diaphragm dielectric elastomer actuators capable of out-of-plane displacement up to 25% of their diameter.
Shea, H. +3 more
core +1 more source
Cutting Edge Bionics in Highly Impaired Individuals: A Case of Challenges and Opportunities
Highly impaired individuals stand to benefit greatly from cutting-edge bionic technology, however concurrent functional deficits may complicate the adaptation of such technology.
Eric J. Earley +16 more
doaj +1 more source
Comparisons of unilateral and bilateral cochlear implantation for children: spatial listening skills and quality of life [PDF]
Recently, controversy in the care of severely-profoundly deaf children has centred on whether they should be provided with bilateral cochlear implants (two implants, one in each ear) rather than a unilateral cochlear implant (one implant in one ear ...
Lovett, Rosemary Elizabeth Susan
core
Restoring tactile feedback via nerve stimulation is essential for intuitive prosthetic control, yet the electrical artifacts introduced by stimulation pulses—especially with modulating amplitudes—can severely distort electromyographic (EMG)
Fabian Just +3 more
doaj +1 more source
Fundamental study on evaluation of the condition of percutaneously implanted electrodes with measuring electrical impedance [PDF]
Restoration of motor functions of paralyzed patients by means of Functional Electrical Stimulation (FES) is effective as a medical treatment. In the clinical application of FES, the traditional evaluation of the electrode failure is difficult and often ...
Murakami, Hajime +3 more
core
Permanent implantation of electrodes for prosthetic control is now possible using an osseointegrated implant as a long-term stable communication interface (e-OPRA).
Mastinu E. +3 more
core +1 more source
System and method for choosing electrodes in an implanted stimulator device [PDF]
A method of selecting of subset of electrodes in a stimulator device implanted in a patient for further clinical evaluation is disclosed. In one embodiment, the method comprises measuring at least first and second measurement for each of the plurality of
Manola, L. +2 more
core
Objective: Literature documenting histopathology of implanted, intracortical electrodes into the human brain is limited. Therefore, we determined the neuropathological changes after chronic intracortical placement of microelectrode arrays within the ...
Liu, Charles +8 more
core
Electrospun membranes for implantable glucose biosensors [PDF]
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel UniversityThe goal for this thesis was to apply electrospun biomimetic coatings on implantable glucose biosensors and test their efficacy as mass-transport limiting ...
Wang, Ning
core