Results 71 to 80 of about 604,287 (319)

Electrochemical method for the determination of arsenic 'in the field' using screen-printed grid electrodes [PDF]

open access: yes, 2008
This project describes development and problem solving efforts to realise a viable portable sensor for arsenic, applicable to drinking water. The work is the first dedicated effort towards this goal, after the preliminary investigations previously ...
Dudeney, Richard
core  

Low‐Cost, Large‐Scale Nanoporous Metals by Mechanical Alloying, Oxide Reduction, and Dealloying of Powders

open access: yesAdvanced Engineering Materials, EarlyView.
Powder metal processing provides scalable advantages in nanoporous (np) metal development. Mechanical alloying is used to produce unique precursors for hybrid nanopore formation by oxide reduction and dealloying. As demonstrated in np Ag, this approach improves process efficiency while promoting smaller ligaments and larger pores, both of which are ...
Mark A. Atwater, Oliver A. Fowler
wiley   +1 more source

Approaching Electroencephalographic Pathological Spikes in Terms of Solitons

open access: yesSignals
A delicate balance between dissipative and nonlinear forces allows traveling waves termed solitons to preserve their shape and energy for long distances without steepening and flattening out.
Arturo Tozzi
doaj   +1 more source

Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest

open access: yesJournal of Family Medicine and Primary Care, 2020
Background: Reusable suction-cup electrodes are used for recording a 12-lead electrocardiogram (ECG) in resource-limited settings. These electrodes may easily detach if those are attached on a hirsute chest.
Himel Mondal   +4 more
doaj   +1 more source

Planar Solid‐State Nanopores Toward Scalable Nanofluidic Integration Based on CMOS Technology

open access: yesAdvanced Engineering Materials, EarlyView.
We present a scalable silicon‐based fabrication strategy for planar solid‐state nanopores to enable their integration with complex nanofluidic systems. Prototype devices demonstrate normal voltage‐current characteristics, good noise performance, and appreciable streaming currents. Our CMOS‐compatible fabrication process offers precise geometric control
Ngan Hoang Pham   +7 more
wiley   +1 more source

Recent progress in microRNA detection using integrated electric fields and optical detection methods

open access: yesFrontiers in Lab on a Chip Technologies
Low-cost, highly-sensitivity, and minimally invasive tests for the detection and monitoring of life-threatening diseases and disorders can reduce the worldwide disease burden.
Logeeshan Velmanickam   +1 more
doaj   +1 more source

Comparative study of AC and DC inclined plane tests on silicone rubber (SiR) insulation

open access: yesHigh Voltage, 2017
Currently there are no international standards for evaluating the tracking and erosion resistance of DC polymeric insulation under contaminated conditions.
Sharif F. Kaaiye   +1 more
doaj   +1 more source

An experimental analysis of thick-film solid-state reference electrodes

open access: yes, 2012
Thick-Film planar solid-state Silver/Silver Chloride (Ag/AgCl) reference electrodes were developed and tested for ion susceptibility and long term drift in approximately 0.04 M potassium chloride (KCl) solution.
Sophocleous, Marios   +3 more
core  

Electrochemical Evaluation of Compressed Selective Laser Melted AlSi7Mg and AlSi10Mg Alloys in Chloride Environment

open access: yesAdvanced Engineering Materials, EarlyView.
The corrosion performance of AlSi7Mg and AlSi10Mg alloys produced through selective laser melting (SLM) was examined under compressive stress in a chloride environment. Electrochemical analyses, including open‐circuit potential (OCP), potentiodynamic polarization (CPP), and electrochemical impedance spectroscopy (EIS), were complemented by scanning ...
Femi John Akinfolarin   +2 more
wiley   +1 more source

Safety of localizing epilepsy monitoring intracranial electroencephalograph electrodes using MRI: radiofrequency-induced heating

open access: yes, 2008
Purpose: To investigate heating during postimplantation localization of intracranial electroencephalograph (EEG) electrodes by MRI. Materials and Methods: A phantom patient with a realistic arrangement of electrodes was used to simulate tissue ...
Lemieux, L.   +6 more
core  

Home - About - Disclaimer - Privacy