Results 31 to 40 of about 379,314 (178)

A Novel Fractal Contact-Electromechanical Impedance Model for Quantitative Monitoring of Bolted Joint Looseness

open access: yesIEEE Access, 2018
Bolted joint are among the key components that enable the robust assembly of a wide variety of structures. However, due to wear and tear over time, bolted joint may loosen, and if not detected in its early stages, can lead to devastating results.
Furui Wang   +3 more
doaj   +1 more source

Digital programming of reciprocity breaking in resonant piezoelectric metamaterials

open access: yesPhysical Review Research, 2023
We demonstrate a digitally controlled piezoelectric metamaterial waveguide leveraging resonant, spatiotem-porally modulated synthetic impedance circuits for programmable reciprocity breaking.
Mustafa Alshaqaq   +2 more
doaj   +1 more source

Adhesive Defect Monitoring of Glass Fiber Epoxy Plate Using an Impedance-Based Non-Destructive Testing Method for Multiple Structures

open access: yesSensors, 2017
The emergence of composite materials has revolutionized the approach to building engineering structures. With the number of applications for composites increasing every day, maintaining structural integrity is of utmost importance.
Wongi S. Na, Jongdae Baek
doaj   +1 more source

An Electromechanical Impedance-Based Application of Realtime Monitoring for the Load-Induced Flexural Stress and Damage in Fiber-Reinforced Concrete

open access: yesFibers, 2023
Effective real-time structural health monitoring in concrete structures is paramount to evaluating safety conditions and the timely maintenance of concrete structures.
Maria C. Naoum   +3 more
doaj   +1 more source

Probabilistic Neural Network and Fuzzy Cluster Analysis Methods Applied to Impedance-Based SHM for Damage Classification

open access: yesShock and Vibration, 2014
Impedance-based structural health monitoring technique is performed by measuring the variation of the electromechanical impedance of the structure caused by the presence of damage.
Lizeth Vargas Palomino   +2 more
doaj   +1 more source

Investigation of electromechanical impedance and residual stress relation for samples machined by hot ultrasonic-assisted turning

open access: yes, 2022
Electromechanical impedance (EMI) method has been widely used in recent years to evaluate the condition of structures. In this method, piezoelectric sensors are added to the structure to examine material properties.
Haydarlar, Gokhan   +6 more
core   +1 more source

Electromechanical Impedance-Based Damage Detection Using Machine Learning Approaches

open access: yesIngeniería e Investigación
Electromechanical impedance-based structural health monitoring has been the subject of extensive research in recent decades. The method’s low cost and ability to detect minor structural damages make it an appealing alternative to other non-destructive ...
Paulo Elias Carneiro Pereira   +4 more
doaj   +1 more source

Evaluation of the Influence of Sensor Geometry and Physical Parameters on Impedance-Based Structural Health Monitoring

open access: yesShock and Vibration, 2012
Structural Health Monitoring (SHM) is the process of damage identification in mechanical structures that encompasses four main phases: damage detection, damage localization, damage extent evaluation and prognosis of residual life.
L.V. Palomino   +5 more
doaj   +1 more source

Electromechanical Anisotropy at the Ferroelectric to Relaxor Transition of (Bi0.5Na0.5)0.94Ba0.06TiO3 Ceramics from the Thermal Evolution of Resonance Curves

open access: yesApplied Sciences, 2018
(Bi0.5Na0.5)0.94Ba0.06TiO3 dense ceramics were obtained from autocombustion sol-gel synthesized nanopowders and sintered at 1050 °C for 1–2 h for the study of the electromechanical anisotropy. Measurement of the complex impedance spectrum was carried out
Nicolás Pérez   +3 more
doaj   +1 more source

Electromechanical Impedance Sensor for In Vivo Monitoring the Body Reaction to Implants

open access: yesJournal of Investigative Surgery, 2004
A novel sensor for in situ monitoring of the body reaction to implants has been developed. A piezoelectric wafer active sensor was adapted for biomedical applications (bio-PWAS). A number of bio-PWAS sensors have been implanted in rats and left in place up to 64 days. The bio-PWAS were able to oscillate in several resonance modes, radial-wise (in-plane)
Victor, Giurgiutiu   +8 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy