Results 121 to 130 of about 4,599 (236)

Navigating the Zero Fluoroscopy Frontier: Current Tools, Evidence and Future Directions in Electrophysiology Procedures

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Graphical Abstract ABSTRACT Fluoroscopy has traditionally been the mainstay imaging technique for guidance during electrophysiology (EP) ablation procedures. The numerous disadvantages associated with radiation exposure for both operators and patients have created the need for zero‐fluoroscopy (ZF) approaches. Today, electrophysiologists have access to
Dimitrios Kotzadamis   +6 more
wiley   +1 more source

First Experience With Extravascular Implantable Cardioverter‐Defibrillator Under Deep Sedation

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background The Extravascular Implantable Cardioverter‐Defibrillator (EV‐ICD) utilizes a substernal lead to provide defibrillation and anti‐tachycardia pacing (ATP) while avoiding transvenous complications. General anesthesia (GA) was applied for implantation procedures in the EV‐ICD pivotal trial and is currently recommended by the ...
Nibras Soubh   +9 more
wiley   +1 more source

Internal Jugular Vein as an Alternative Access for Pacemaker Implantation: A Mostly Left IJ Case Series

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Leadless pacemakers traditionally rely on femoral venous access, which may be limited in patients with unfavorable IVC anatomy, prior interventions, or situations where preserving femoral access is preferred. Internal jugular (IJ) access offers an alternative route, but real‐world data on IJ implantation of single‐ and dual‐chamber ...
Maya Asami Takagi   +3 more
wiley   +1 more source

Ventricular Synchrony in Targeted Right Ventricular Septal Pacing: A Prospective Paired Comparison to Apical Placement

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background/Objectives Right ventricular (RV) apical pacing, the standard pacing approach, often induces ventricular dyssynchrony, potentially impairing cardiac function. This study aims to investigate whether targeted RV septal pacing, guided by functional electrophysiological feedback during implantation, reduces ventricular dyssynchrony ...
Bianca Iulia Catrina   +5 more
wiley   +1 more source

Diagnostic Accuracy of 12‐Lead ECG Algorithms for Accessory Pathway Localization in WPW: A Meta‐Analysis

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background In Wolff–Parkinson–White (WPW) syndrome, accurate localization of accessory pathways before catheter ablation can improve procedural planning and efficiency. Several 12‐lead electrocardiographic (ECG) algorithms have been proposed, but their diagnostic performance has not been consistently established.
Elsayed S. Moubarak   +19 more
wiley   +1 more source

Home - About - Disclaimer - Privacy