Results 91 to 100 of about 128,425 (312)
To the Editor: I read the recent report by Gilleard and colleagues (January 1998) with great interest, in the hope that the study would shed more light on the issue of relative timing of vastus medialis oblique muscle (VMO) and vastus lateralis muscle (VL) electromyographic (EMG) activity during voluntary activation.
openaire +2 more sources
Muscle Control of an Extra Robotic Digit
This study compares muscle‐ and movement‐based control for operating a supernumerary robotic thumb. While movement control performs better in the proposed tasks, muscle‐based (EMG) control promotes broader motor learning. The results highlight the promise and challenges of using biosignals for human augmentation, offering new insights into intuitive ...
Julien Russ +7 more
wiley +1 more source
Background: Urinary incontinence affects one in three women worldwide. Pelvic floor muscle training is an effective treatment. Electromyography biofeedback (providing visual or auditory feedback of internal muscle movement) is an adjunct that may improve
Suzanne Hagen +23 more
doaj +1 more source
Here, we present a textile, wearable capacitive interface enabling multidirectional remote control by dynamically modulating electrode overlap and spacing via a freely gliding upper electrode. A forearm‐mounted prototype drives robotic and media tasks with 12–15 ms latency, maintains < 0.8% drift after 500 cycles, and remains stably functional at 90 ...
Cagatay Gumus +8 more
wiley +1 more source
Optimisation of EMG sensors printing and their characterisation
openL'elettromiografia di superficie (sEMG) è un metodo per registrare l'attività elettrica dei muscoli, che fornisce informazioni preziose riguardo alla loro contrazione e rilassamento.
MARCOLONGO, PIETRO
core
Estimation of Muscle Fiber Conduction Velocity from Simulated Surface EMG in Pinnate Muscles [PDF]
Udgivelsesdato: MAR ...
Damiano, Luisa +6 more
core +1 more source
Deglutition dynamics of patients with obstructive sleep apnea
Objectives: In the present study, we performed a detailed analysis of deglutitive dynamics during sleep in patients with obstructive sleep apnea (OSA) using a methodology developed by Sato et al.
Satoshi Ito +10 more
doaj +1 more source
Strategic Design of Soft Actuators in Translational Medical Robotics for Human‐Centered Healthcare
Soft robotics enables biocompatible, compliant medical devices, but clinical translation requires design‐driven engineering beyond materials. This perspective reviews implantable, surgical, and wearable systems by actuation mechanism, highlighting how optimized architectures and integration improve mechanical interfacing, adaptability, and durability ...
Ho Jun Jin +3 more
wiley +1 more source
EMG létrejötte - Striker György szerepe
Az EMG megalakulásának bemutatása az Egyesült Izzó és az Orion vállalatokon keresztül Striker György munkássága ...
Forgács, András
core
Estimation of Muscle Fiber Conduction Velocity from Surface EMG Recordings by Optimal Spatial Filtering [PDF]
Udgivelsesdato ...
Farina, D. +6 more
core +1 more source

