Results 1 to 10 of about 2,919 (107)

Modelización de línea aérea de distribución rural para evaluación del desempeño ante descargas atmosféricas aplicado al software EMTP RV

open access: yesProspectiva Universitaria, 2022
El presente trabajo de investigación tuvo como problema general el cómo modelar la línea aérea de distribución rural para evaluar su desempeño ante descargas atmosféricas aplicado al software EMTP RV. Se utilizó el método de modelización y simulación, considerando el procedimiento secuencial: Descripción del problema, construcción de unmodelo ...
Catay Buitrón, Abel César
openaire   +3 more sources

Evaluation of Filtered Spark Gap on the Lightning Protection of Distribution Transformers: Experimental and Simulation Study

open access: yesEnergies, 2020
Protection of transformers, as one of the most expensive equipment in the power system, against lightning overvoltage impulses is a vital task. This paper, for the first time so far, investigates the effects of a filtered spark gap on the protection ...
Mahdi Pourakbari-Kasmaei   +6 more
doaj   +1 more source

Impacts of Lightning-Induced Overvoltage on a Hybrid Solar PV–Battery Energy Storage System

open access: yesApplied Sciences, 2021
With increased electrical energy demands projected in the future, the development of a hybrid solar photovoltaic (PV)–battery energy storage system is considered a good option. However, since such systems are normally installed outdoors and in open areas,
Nor Izzati Ahmad   +5 more
doaj   +1 more source

THE EFFECTS OF CABLE CHARACTERISTICS ON MAXIMUM OVERVOLTAGE IN COMBINED OVERHEAD/CABLE LINES PROTECTED BY SURGE ARRESTERS

open access: yesInternational Islamic University Malaysia Engineering Journal, 2018
 This paper presents the calculation of maximum lightning overvoltage for a transmission system consisting of overhead lines in combination with an underground power cable.
Reza Alizadeh, Mohammad Mirzaie
doaj   +1 more source

Monte-Carlo-based simulation and investigation of 230 kV transmission lines outage due to lightning

open access: yesHigh Voltage, 2019
Here, using the probabilistic evaluation based on the Monte Carlo method, back-flashover rate and shielding failure flashover rate of 230 kV overhead transmission lines in the western regions of Iran are evaluated.
Ehsan Karami   +3 more
doaj   +1 more source

Evaluating the High Frequency Behavior of the Modified Grounding Scheme in Wind Farms

open access: yesApplied Sciences, 2017
Wind generators are exposed to numerous destructive forces such as lightning and are therefore vulnerable to these phenomena. To evaluate the transient behavior of a wind power plant during direct and indirect strikes, modeling of all relevant components
Seyede Fatemeh Hajeforosh   +3 more
doaj   +1 more source

Localization of partial discharge in the high voltage apparatus

open access: yesResults in Control and Optimization
Partial discharges (PD) in high-voltage (HV) devices can be used as indicators of insulation deterioration, often preceding catastrophic failures in power systems.
Amir Ghaedi   +3 more
doaj   +1 more source

High-speed and accurate detection of high-impedance arcing faults in renewable energy microgrids using a master-slave ADALINE algorithm

open access: yesAin Shams Engineering Journal
High-Impedance Arcing Faults (HIAFs) in electrical microgrids are among the abnormal conditions that are difficult to detect by conventional protective devices due to low current and non-linear behavior. In addition, the behavioral similarity of HIAFs to
Mohsen Jannati, Hamidreza Toodeji
doaj   +1 more source

Optimal Location of Surge Arrester for Protection of 220kV Transmission Line Against Lightning Over Voltages Using EMTP-RV Software

open access: yesEngineering and Technology Journal
Natural Lightning strikes are the main cause of over voltages in the power system. Such lightning over voltages can damage the system insulation if sufficient protections are not provided to the system. In the power system ground wire or shield wires are placed on top of the transmission line tower for the protection of transmission lines against ...
Shaswat, Dwivedi   +2 more
openaire   +2 more sources

An efficient deep learning based scheme for adaptive auto-reclosing in power transmission lines

open access: yesAlexandria Engineering Journal
As a large percentage of faults in transmission lines are single-line-to-ground (SLG) and transient in nature, the use of adaptive single-phase auto-reclosing (ASPAR) schemes is essential.
Farhad Hatami Aloghareh   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy