An Advanced Interface Between the LIOV Code and the EMTP-RV
Accurate evaluation of the response of overhead distribution lines to lightning electromagnetic pulse (LEMP) represents an important aspect in insulation coordination of distribution networks. The improvement of the accuracy of such an analysis calls for
PAOLONE, MARIO +5 more
core +1 more source
Load-flow computation using EMTP-RV program package
Unutar elektroenergetskog sustava nalazi se mnoštvo grana i čvorova, vodovi i transformatori definiraju grane sustava, a sabirnice su čvorovi. Potrošnja snage u sustavu tokom cijelog dana se mijenja, te iz toga razloga radne točke generatora se mijenjaju
Kasalo, Ante
core +4 more sources
Modellizzazione di celle Na-Beta per l'accumulo elettrochimico stazionario [PDF]
Costruzione di modelli in EMTP-RV delle celle, moduli, unità delle batterie sodio-zolfo e delle sodio-cloruro di nichel. Costruzione dei modelli dei convertitori in EMTP-RV dei sistemi di accumulo sulla rete di trasmissione (150 kV ...
Benetti, Riccardo
core
High impedance faults (HIFs) can lead to crucial damage to the utility grid, such as the risk of fire in material assets, electricity supply interruptions, and long service restoration times.
Mohammad Sadegh Attar +1 more
doaj +1 more source
Le modèle d'information commun : description et migration des données CIM-XML vers le format EMTP-RV [PDF]
Le modèle CIM -- Traitement de documents XML -- La plate-forme.net -- Extraction des données CIM-XML : procédure pas-à-pas -- Transfert des données CIM-XML vers EMTP-RV -- Interface activex -- Les services ...
Ndiaye, Awa Marie
core
The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV ...
F. Amanifard, N. Ramezani
doaj
Modélisation du four à arc dans le logiciel EMTP-RV [PDF]
Four à courant continu -- Qu'est-ce qu'un four à arc cc? -- Présentation du montage sous EMTP-RV -- Les transformateurs -- Convertisseur ca/cc -- Convertisseur cc/cc -- Modèle de l'arc électrique du four cc -- Résultats -- Four à courant alternatif ...
Lkoun, Hassiba
core
The Lightning Protection Assessment of Distribution Lines with Considering Frequency Grounding System [PDF]
Ensuring the protection of all components within power systems from lightning-induced overvoltage is crucial. The issue of power interruptions caused by both direct and indirect lightning strikes (LS) presents significant challenges in the electrical ...
Aida Gholami +2 more
doaj
Réalisation d'un modèle d'interconnexion CCHT sous EMTP-RV [PDF]
Ce document traite de la réalisation d'une interconnexion CCHT sous EMTP-RV. Les travaux effectués dans ce domaine sont tout d'abord passés en revue. La problématique liée à cette technologie est ensuite présentée.
Paquin, Jean-Nicolas
core +1 more source
Novel Techniques to Reduce Transformer Inrush Current Using EMTP Software
Transformer inrush current is a high-amplitude, non-sinusoidal transient that occurs during initial energization, leading to voltage dips, power quality degradation, and relay misoperations.
Amir Ghaedi +2 more
doaj