STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES [PDF]
Abstrak Electric energy has been transmiting from power station to end user with transmission and distribution lines. Lightning strokes are problems that occure in transmission and distribution lines and make them fault when the electric energy were ...
Liliyana NS, Liliyana NS +2 more
core
Model Arrester SiC Menggunakan Model Arrester ZnO IEEE WG 3.4.11 [PDF]
Arrester model is needed to analyse the insulation coordination in power system. The model should give a suitable respon for varying transient fault. In this paper, we conduct simulation that modified from IEEE WG 3.4.11 model.
Haryono, T. (T) +2 more
core
Winding-to-ground fault location in power transformer windings using combination of discrete wavelet transform and back-propagation neural network. [PDF]
Chiradeja P, Ngaopitakkul A.
europepmc +1 more source
Selection and coordination of surge arresters for switching transient mitigation in photovoltaic power plants [PDF]
: Photovoltaic energy generation has become a popular renewable alternative to conventional energy generation that utilise fossil fuels. However, given the diversity and complexity of these PV plants, it is imperative that such plant equipment be ...
Bokoro, P. +3 more
core
Large transient fault current test of an electrical roll ring [PDF]
The space station uses precision rotary gimbals to provide for sun tracking of its photoelectric arrays. Electrical power, command signals and data are transferred across the gimbals by roll rings.
Birchenough, Arthur G., Yenni, Edward J.
core +1 more source
一、引言 变电所防止雷电与操作过电压中,GIS的保护性能在许多重要方面与敞开式的变电站不同。传统变电站的绝缘水平主要取决于变压器的保护物——避雷器的正确选择及它们的安装位置;它的空气绝缘的强度可以自动恢复,开关可以耐受如绝缘子或套管闪络这样的故障。而GIS的绝缘不具有自动恢复的这个特性,在遭受过电压时,故整个GIS系统(母线,断路器,隔离开关和接地开关等)必须得到全面的保护。另外,架空线的进线段到GIS开关之间的母线也同样需要保护。GIS装置中 ...
施围
doaj
Emergency Medical Services in Taiwan: Past, Present, and Future. [PDF]
Huan TL +12 more
europepmc +1 more source
Modelling and simulation of three-phase power transformers [PDF]
This paper presents the development and implementation of a digital simulation model of a three-phase, three-leg, power transformer. The proposed model, implemented in MATLAB environment, is based on the physical concept of representing windings as ...
Cardoso, A. J. Marques +1 more
core
Algoritmos para localización de fallas en líneas de transmisión, análisis para el caso colombiano
Se analizan cuatro algoritmos localizadores de fallas en líneas de transmisión, aplicados en el sistema de transmisión nacional colombiano. Se determina cual es más preciso y eficiente. Finalmente, se verifican por medio de simulaciones en EMTP/ATP, y
Gina M. Idárraga Ospina +2 more
doaj
Wide-band modelling of tower-footing grounding systems based on the impulse response measurement [PDF]
The tower footing grounding system is of major importance for analysis of the lightning overvoltages on an overhead transmission line during backflashover and shielding failure.
Jasika Ranko +3 more
doaj