Results 1 to 10 of about 593,550 (63)
Pyloric sphincter characteristics using EndoFLIP® in gastroparesis
Introduction and aims: Pyloric sphincter abnormalities may be detected in gastroparesis. Botulinum toxin A (BoNT/A) injection into the pylorus has been used to treat gastroparesis with varying results. The aim of the present article was to assess whether
M. Saadi +4 more
doaj +2 more sources
Características del esfínter pilórico utilizando EndoFLIP® en gastroparesia
Resumen: Introducción y objetivos: Existen anormalidades en el esfínter pilórico que pueden ser detectadas en la gastroparesia. La inyección de toxina botulínica tipo A (BoNT/A) en el píloro ha sido utilizada en el tratamiento de gastroparesia con ...
M. Saadi +4 more
doaj +2 more sources
The Functional Lumen Imaging Probe (EndoFLIP®) system is an impedance-based technology providing real-time measurements of cross-sectional area (CSA) and intraballoon pressure across a luminal segment.
Theodoros A. Voulgaris +6 more
doaj +2 more sources
Swallowing impairment is a highly prevalent and clinically significant problem affecting people and dogs. There are myriad causes of swallowing impairment of which gastroesophageal reflux is the most common in both species.
Tarini V. Ullal +4 more
doaj +1 more source
Resumen: El sistema de EndoFLIP® (sonda de imagen funcional luminal) es una herramienta que utiliza la planimetría por impedancia de alta resolución y mide el área de sección transversal en un plano axial del tubo digestivo.
L.R. Valdovinos-García +3 more
doaj +1 more source
Endoluminal functional lumen imaging probe (EndoFLIP®) is a device that uses high-resolution impedance planimetry to measure the cross-sectional area of the gastrointestinal tract along an axial plane.
L.R. Valdovinos-García +3 more
doaj +1 more source
® system in patients with gastroparesis
International audienceAbstract Background Pyloric distensibility has been reported as a predictive measure in gastroparesis. Measures can be obtained either during endoscopy under anesthesia or in unsedated patients.
Jérémie Jacques +11 more
core +1 more source
S.3353-3359A dilated gastrojejunal anastomosis (GJA) diameter is an independent predictor of weight regain following Roux-en-Y gastric bypass (RYGB). Despite this, there is no standardized method for GJA diameter measurement. We performed a retrospective
Itani, Mohamad I. +13 more
core +1 more source
International audienceAbstract Background Pyloric distensibility has been reported as a predictive measure in gastroparesis. Measures can be obtained either during endoscopy under anesthesia or in unsedated patients.
Jérémie Jacques +13 more
core +1 more source
Utility of Functional Lumen Imaging Probe in Long-Term Follow-Up of Children with Esophageal Atresia: A Single-Center Retrospective Study [PDF]
Long term follow-up of patients with esophageal atresia (EA) may be hampered by esophageal dysmotility, which affects quality of life and might lead to late complications. The endoluminal functional lumen imaging probe (EndoFlip™ Medtronic, Crospon
Durante, Eleonora +17 more
core +1 more source

