Results 1 to 10 of about 593,550 (63)

Pyloric sphincter characteristics using EndoFLIP® in gastroparesis

open access: yesRevista de Gastroenterología de México (English Edition), 2018
Introduction and aims: Pyloric sphincter abnormalities may be detected in gastroparesis. Botulinum toxin A (BoNT/A) injection into the pylorus has been used to treat gastroparesis with varying results. The aim of the present article was to assess whether
M. Saadi   +4 more
doaj   +2 more sources

Características del esfínter pilórico utilizando EndoFLIP® en gastroparesia

open access: yesRevista de Gastroenterología de México, 2018
Resumen: Introducción y objetivos: Existen anormalidades en el esfínter pilórico que pueden ser detectadas en la gastroparesia. La inyección de toxina botulínica tipo A (BoNT/A) en el píloro ha sido utilizada en el tratamiento de gastroparesia con ...
M. Saadi   +4 more
doaj   +2 more sources

Functional Lumen Imaging Probe (EndoFLIP) in Upper Gastrointestinal Disorders: Current Evidence, Clinical Applications, and Future Perspectives

open access: yesDiseases
The Functional Lumen Imaging Probe (EndoFLIP®) system is an impedance-based technology providing real-time measurements of cross-sectional area (CSA) and intraballoon pressure across a luminal segment.
Theodoros A. Voulgaris   +6 more
doaj   +2 more sources

A Comparative Assessment of the Diagnosis of Swallowing Impairment and Gastroesophageal Reflux in Canines and Humans

open access: yesFrontiers in Veterinary Science, 2022
Swallowing impairment is a highly prevalent and clinically significant problem affecting people and dogs. There are myriad causes of swallowing impairment of which gastroesophageal reflux is the most common in both species.
Tarini V. Ullal   +4 more
doaj   +1 more source

EndoFLIP® en la evaluación funcional del tracto gastrointestinal: estado actual y perspectivas clínicas

open access: yesRevista de Gastroenterología de México
Resumen: El sistema de EndoFLIP® (sonda de imagen funcional luminal) es una herramienta que utiliza la planimetría por impedancia de alta resolución y mide el área de sección transversal en un plano axial del tubo digestivo.
L.R. Valdovinos-García   +3 more
doaj   +1 more source

EndoFLIP® in the functional evaluation of the gastrointestinal tract: Current status and clinical perspectives

open access: yesRevista de Gastroenterología de México (English Edition)
Endoluminal functional lumen imaging probe (EndoFLIP®) is a device that uses high-resolution impedance planimetry to measure the cross-sectional area of the gastrointestinal tract along an axial plane.
L.R. Valdovinos-García   +3 more
doaj   +1 more source

® system in patients with gastroparesis

open access: yes, 2023
International audienceAbstract Background Pyloric distensibility has been reported as a predictive measure in gastroparesis. Measures can be obtained either during endoscopy under anesthesia or in unsedated patients.
Jérémie Jacques   +11 more
core   +1 more source

The utility of EndoFLIP for measuring gastrojejunal anastomosis diameter and distensibility in patients experiencing weight regain post Roux-en-Y gastric bypass

open access: yes, 2022
S.3353-3359A dilated gastrojejunal anastomosis (GJA) diameter is an independent predictor of weight regain following Roux-en-Y gastric bypass (RYGB). Despite this, there is no standardized method for GJA diameter measurement. We performed a retrospective
Itani, Mohamad I.   +13 more
core   +1 more source

Multitraction with a single rubber band and clips: a simple tip for endoscopic submucosal dissection of a recurrent lesion with previous clip

open access: yes, 2023
International audienceAbstract Background Pyloric distensibility has been reported as a predictive measure in gastroparesis. Measures can be obtained either during endoscopy under anesthesia or in unsedated patients.
Jérémie Jacques   +13 more
core   +1 more source

Utility of Functional Lumen Imaging Probe in Long-Term Follow-Up of Children with Esophageal Atresia: A Single-Center Retrospective Study [PDF]

open access: yes, 2022
Long term follow-up of patients with esophageal atresia (EA) may be hampered by esophageal dysmotility, which affects quality of life and might lead to late complications. The endoluminal functional lumen imaging probe (EndoFlip™ Medtronic, Crospon
Durante, Eleonora   +17 more
core   +1 more source

Home - About - Disclaimer - Privacy