Results 111 to 120 of about 2,607 (169)
Abstract Objectives Acute cerebral ischemia is characterized by several pathological processes evolving during time, which contribute to the final tissue damage. Secondary processes, such as prolonged inflammatory response, impaired mitochondrial function and oxidative stress, are responsible for the progression of brain injury to the peri‐infarct area,
Fioravante Capone +8 more
wiley +1 more source
ABSTRACT Objectives To evaluate the feasibility and short‐term outcomes of transcatheter aortic valve replacement (TAVR) using balloon‐expandable Sapien valves in patients with prior endovascular aortic stent grafts. Methods We conducted a single‐center, retrospective study of 23 patients with prior endovascular aortic stent grafts who underwent TAVR ...
Iad Alhallak +8 more
wiley +1 more source
Clinical Effect Analysis of Spinal Cord Electrical Stimulator Implantation for Diabetic Foot
Abstract Objective To investigate the clinical effect of spinal cord electrical stimulator implantation in the treatment of diabetic foot (DF). Materials and Methods We recruited 19 patients with DF who were admitted to Shengjing Hospital of China Medical University between January 2018 and May 2020.
Peng‐Bo Zhou, Min Bao
wiley +1 more source
ABSTRACT Background Intravascular lithotripsy (IVL) has emerged as an effective technique for modifying heavily calcified coronary plaques, facilitating optimal stent expansion while minimizing procedural complications. However, data on periprocedural myocardial injury (PMI) and infarction (PPMI) following IVL remain scarce.
Gwaenaelle Aellen +5 more
wiley +1 more source
ABSTRACT Background Biodegradable‐polymer (BP) drug‐eluting stents (DES) were developed to mitigate potential late adverse events related to persistent durable polymers in durable‐polymer (DP) DES; however, contemporary long‐term real‐world comparative data remain limited. Aims We aimed to compare the 5‐year clinical outcomes of contemporary BP‐DES and
Yangyoun Lee +6 more
wiley +1 more source
Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN‐3 Balloon
ABSTRACT Balloon rupture during transcatheter aortic valve replacement (TAVR) with balloon‐expandable valves is a rare but potentially serious complication that may result in incomplete valve expansion, difficult device retrieval, and vascular injury.
Anne Venkata Ganeshkumar +5 more
wiley +1 more source
ABSTRACT Incomplete stent apposition at the proximal coronary artery may predispose to subtle guiding catheter–induced stent deformation, creating a gap between the stent and the vessel wall that facilitates inadvertent abluminal guidewire passage. We report a case in which balloon dilatation over an unrecognized abluminal guidewire resulted in severe ...
Yuto Abe +3 more
wiley +1 more source
Radiation Reduction in the Catheterization Laboratory: Beyond the Angiography System
Catheterization and Cardiovascular Interventions, EarlyView.
Sundar Chidambaram, Manokar Panchanatham
wiley +1 more source
ABSTRACT Background The prognostic benefit of revascularization for unprotected left main (LM) disease remains uncertain, as guideline endorsement of percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) precludes comparison with deferral, which is unlikely to be assessed in a randomized trial.
Marc Meller Bröchner +10 more
wiley +1 more source
ABSTRACT The case regards a 73‐year‐old male who was referred for consideration of percutaneous left atrial appendage closure. His left atrial appendage was ligated during prior mitral valve surgery, but was noted to be patent on a recent transesophageal echocardiography. An Amulet device was selected based on CT planning.
Zach Rozenbaum, Eric Gnall
wiley +1 more source

