Results 1 to 10 of about 1,178 (99)
Assessing energy saving potential of wavelength-dependent passive daytime radiative cooler implemented with EnergyPlus by a roof model [PDF]
The Passive Daytime Radiative Cooler (PDRC) exhibits potential in enhancing building energy conservation due to its high emissivity in wavelength between 8 μm and 13 μm.
Yujie Yang, Guoqiang Zhang, Li Rong
doaj +2 more sources
Energo koncept Yaodong podzemnih zgrada u XXI veku na teritoriji Srbije
Zbog svog zanimljivog arhitektonskog rešenja, podzemne zgrade Yaodong kao da nude balans između prirodnih i stvorenih parametara lokacije (s jedne strane) i ambijentalnog komfora (s druge strane).
Aleksandar Nešović +2 more
doaj +1 more source
In this study, seven of the most commonly applied covering materials in smart farms are selected as the representative samples for analysis, namely, glass, soft film (polyethylene, PE), soft film (polyolefin, PO), rigid plastic film (ethylene tetra ...
Doo-Yong Park +3 more
doaj +1 more source
This paper investigates the thermal performance of green roofs, cool roofs, and their combined effects in tropical climates. Although each technology has been studied independently for its potential to reduce cooling energy consumption in buildings ...
Mdlalose Nonkululeko Portia +3 more
doaj +1 more source
Krovovi i zidovi zgrada predstavljaju značajnu lokaciju za instalaciju fotonaponskih sistema u urbanim sredinama. Soliteri, sa specifičnim prostornim oblikom, pružaju mogućnost instalacije ovih sistema i na krovu i na spoljašnjim zidovima.
Andreja Stefanović
doaj +1 more source
Lineamientos para la implementación BIM en la evaluación ambiental de la vivienda social
Las innovaciones en ciencia y tecnología desempeñan un papel fundamental en la transición hacia producciones más limpias. Con base en ello, este artículo busca favorecer la integración práctica de conceptos propios de arquitectura bioclimática en el ...
Analía Alejandra Alvarez +3 more
doaj +1 more source
TOWARD FUTURE: POSITIVE NET-ENERGY BUILDINGS [PDF]
For a positive net building (PNEB), the paper presents its need, and tools to achieve its design. The PNEB should provide the maximum thermal comfort with a minimum of energy, primary energy, and exergy consumption, .and reduction of the use of energy ...
Jasmina Skerlić +4 more
doaj +1 more source
The paper aims to explore the effect of different passive cooling measures using thermal modelling and predicting. Solar shading, green roofs and cool paints were incorporated as passive cooling measures to evaluate their combined effects on indoor ...
Oluwatimilehin P. Olawale-Johnson +2 more
doaj +1 more source
The cultivation of crops in greenhouses is well established in China. However, the greenhouse climate is complex, rendering it difficult to analyze the greenhouse load and control the energy supply system.
Chongyi Tian +5 more
doaj +1 more source
Analysis of the potential use of Trombe walls in Brazil: design recommendations
In this paper, the thermal performance of a standard environment was evaluated based on the use of a Trombe wall with different configurations and types of use, as the potential for using this passive strategy is still little studied in Brazil.
de Melo Sá Cavalcanti Fernando Antonio +1 more
doaj +1 more source

