Results 161 to 170 of about 518,567 (266)

Highly Sensitive Electrochemical Biosensor Based on Hairy Particles with Controllable High Enzyme Loading and Activity

open access: yesAdvanced Functional Materials, EarlyView.
For the first time, a highly sensitive electrochemical biosensor based on SiO2‐based hairy particles with a grafted PDMAEMA polymer brush containing a quantifiable and large amount of immobilized Laccase is reported. The fabricated biosensor exhibits a sensitivity of 0.14 A·m⁻¹, a limit of detection (LOD) of 0.1 µm, and a detection range of 0.3–750 µm,
Pavel Milkin   +7 more
wiley   +1 more source

Residential Proximity to NPL Superfund Sites and High Particulate Matter Exposure Is Associated with Increased Likelihood of Triple-Negative Breast Cancer. [PDF]

open access: yesCancer Epidemiol Biomarkers Prev
Borowsky PA   +9 more
europepmc   +1 more source

MOFs and COFs in Electronics: Bridging the Gap between Intrinsic Properties and Measured Performance

open access: yesAdvanced Functional Materials, EarlyView.
Metal‐organic frameworks (MOFs) and covalent organic frameworks (COFs) hold promise for advanced electronics. However, discrepancies in reported electrical conductivities highlight the importance of measurement methodologies. This review explores intrinsic charge transport mechanisms and extrinsic factors influencing performance, and critically ...
Jonas F. Pöhls, R. Thomas Weitz
wiley   +1 more source

Bimetallic Nanoreactor Activates cGAS‐STING Pathway via mtDNA Release for Cancer Metalloimmunotherapy

open access: yesAdvanced Functional Materials, EarlyView.
A bimetallic Mn–Ca nanoreactor (MCC) is developed as a non‐nucleotide STING nanoagonist for cancer metalloimmunotherapy. MCC induces Ca2+ overload and hydroxyl radical generation, resulting in mitochondrial damage and mtDNA release. The released mtDNA cooperates with Mn2+ to robustly activate cGAS–STING signaling.
Xin Wang Mo   +7 more
wiley   +1 more source

PEDOT‐Based Eutectogel Electrode Arrays for Enhanced High‐Resolution Electrogastrography: Fabrication, Stability, and Wearable Performance

open access: yesAdvanced Functional Materials, EarlyView.
Here, we present a high‐density PEDOT eutectogel electrode array for enhanced body surface gastric mapping. Silver electrodes are blade‐coated onto flexible substrates, followed by electrogelation of PEDOT:PSS and the deposition of a PEDOT:LS eutectogel.
Christopher Slaughter   +8 more
wiley   +1 more source

Association of air pollution and atmospheric conditions on pulmonary embolism incidence and severity. [PDF]

open access: yesRes Pract Thromb Haemost
Nopp S   +5 more
europepmc   +1 more source

Spectrally Tunable 2D Material‐Based Infrared Photodetectors for Intelligent Optoelectronics

open access: yesAdvanced Functional Materials, EarlyView.
Intelligent optoelectronics through spectral engineering of 2D material‐based infrared photodetectors. Abstract The evolution of intelligent optoelectronic systems is driven by artificial intelligence (AI). However, their practical realization hinges on the ability to dynamically capture and process optical signals across a broad infrared (IR) spectrum.
Junheon Ha   +18 more
wiley   +1 more source

Home - About - Disclaimer - Privacy