Setup Error Differences and Margin Expansion Among Rectal Cancer Segments: Consistency Evaluation Between EPID and iSCOUT [PDF]
Purpose To analyze the differences in setup errors among patients with rectal cancer in the upper, middle and lower segments and evaluate the consistency between electronic portal imaging device (EPID) and iSCOUT image‐guided techniques.
Bao Wan +10 more
doaj +2 more sources
Development of Artificial Intelligence as a Conversion Tool for Cine Electronic Portal Imaging Device Images to Radiotherapy Dosimetry: Preliminary Study [PDF]
Introduction: This research is a preliminary study of the development of Artificial Intelligence (AI) as a conversion tool from the pixel value of Cine a-Si 1000 Electronic Portal Imaging Device (EPID) images to dose.
Muhammad Ramadhan +2 more
doaj +1 more source
Clinical Experience of Intensity Modulated Radiotherapy Pre-Treatment Quality Assurance for Carcinoma Head and Neck Patients with EPID and IMatriXX in Rural Center [PDF]
Background: Radiation therapy techniques as Intensity Modulated Radiotherapy (IMRT), rapid arc have been used for treatment of cancer with high accuracy.
M More, V Jain, O P Gurjar
doaj +1 more source
Development of an Electronic Portal Imaging Device Dosimetry Method
Support arm backscatter and off-axis effects of an electronic portal imaging device (EPID) are challenging for radiotherapy quality assurance. Aiming at the issue, we proposed a simple yet effective method with correction matrices to rectify backscatter ...
Jun Zhang +4 more
doaj +1 more source
An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm [PDF]
Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study,
S M Hashemi +8 more
doaj +1 more source
Breast in vivo dosimetry by EPID
An electronic portal imaging device (EPID) is an effective detector for in vivo transit dosimetry. In fact, it supplies two‐dimensional information, does not require special efforts to be used during patient treatment, and can supply data in real time.
Fidanzio, Andrea +9 more
+7 more sources
Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic.
van Asselen, B +7 more
core +10 more sources
Objectives: This study performed dosimetry studies and secondary cancer risk assessments on using electronic portal imaging device (EPID) and cone beam computed tomography (CBCT) as image guided tools for the early lung cancer patients treated with SBRT.
Yan-Hua Duan ME +12 more
doaj +1 more source
wzbillings/EPID-8130-Final-Paper: Final paper draft
<p>This is the final draft of my paper for EPID 8130. Future updates will not edit the content of the paper unless absolutely necessary (or based on feedback after grading).</p> <p>In this work, I perform a systematic review of ...
Zane Billings
core +1 more source
Verification of IMRT and RapidArc Localized Prostate Cancer Treatment Plans Using EPID and Delta4 in vivo Dosimetry Methods [PDF]
Background: Quality assurance for intensity modulated radiation therapy (IMRT) depends on the type of dosimetry system and its evaluation procedure. We can check both the intensity and distribution of each field as the required pretreatment verification ...
Moustafa Ahmed +4 more
doaj +1 more source