Contrast enhancement of EPID images via difference imaging : a feasibility study [PDF]
In this study, the feasibility of difference imaging for improving the contrast of electronic portal imaging device (EPID) images is investigated. The difference imaging technique consists of the acquisition of two EPID images (with and without the ...
Khoei, Shadi +9 more
core +1 more source
EPID in vivo dosimetry in RapidArc technique [PDF]
The aim of the study was to estimate the dose at the reference point applying an aSi-EPID device in the course of patient treatment.The method assumes direct proportionality between EPID signal and dose delivered to the patient reference point during the treatment session.
Slosarek, Krzysztof +3 more
openaire +2 more sources
A Validation Method for EPID In Vivo Dosimetry Algorithms [PDF]
The aim of this study was to develop and apply an evaluation method for assessing the accuracy of a novel 3D EPID back-projection algorithm for in vivo dosimetry. The novel algorithm of Dosimetry Check (DC) 5.8 was evaluated. A slab phantom homogeneously filled, or with air and bone inserts, was used for fluence reconstruction of different squared ...
Marco Esposito +5 more
openaire +3 more sources
Flexibility and efficiency in a radiotherapy department with different linear accelerators (linacs) can be improved if they are dosimetrically equivalent, and there is no need of plan or patient-specific quality assurance (PSQA) modification.
José Alejandro Rojas-López +1 more
doaj +1 more source
Aims: This study investigates the impact of cine acquisition mode on the dosimetric characteristics of a Varian aS500 amorphous silicon electronic portal imaging device (a-Si EPID).
Omemh Bawazeer +4 more
doaj +1 more source
The dose delivery verification for a head and neck static intensity modulated radiation therapy (IMRT) case using a scanning liquid ionization chamber electronic portal imaging device (SLIC-EPID) was investigated.
Mohammad Mohammadi, Eva Bezak
doaj +1 more source
Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices for Other applications for Linear Accelerator Quality Assurance [PDF]
Introduction: The success of radiation therapy depends critically on the accuracy of patient alignment in treatment position day after day. The primary use for Electronic portal imaging devices (EPIDs) is to monitor patient position during daily ...
Gena Mohamed +3 more
doaj +1 more source
The use of the transit-EPID images in the radiotherapy quality assurance – literature review [PDF]
Wraz z rozwojem coraz bardziej złożonych technik napromieniania pacjenta wiązkami zewnętrznymi, weryfikacja prawidłowości ich realizacji staje się coraz większym wyzwaniem.
Borowska, Patrycja +2 more
core
PURPOSE:The goal of this study was to investigate the effectiveness of monitoring relevant variations during treatments for electronic portal imaging device (EPID)-based 3D in vivo verification performed using planning CTs.
Yinghui Li +4 more
doaj +1 more source