EPID-based in vivo dosimetry – new developments and applications
In vivo dosimetry has been shown to be a powerful quality assurance method in modern radiation therapy. The most common tool used for in vivo dosimetry is the electronic portal imaging device (EPID) which can quantitatively image the therapeutic beam ...
B. McCurdy
semanticscholar +1 more source
In-vivo quality assurance of dynamic tumor tracking (DTT) for liver SABR using EPID images.
PURPOSE To assess dynamic tumor tracking (DTT) target localization uncertainty for in-vivo marker-based stereotactic ablative radiotherapy (SABR) treatments of the liver using electronic-portal-imaging-device (EPID) images.
Rostamzadeh Maryam +8 more
semanticscholar +1 more source
Verification of IMRT and RapidArc Localized Prostate Cancer Treatment Plans Using EPID and Delta4 in vivo Dosimetry Methods [PDF]
Background: Quality assurance for intensity modulated radiation therapy (IMRT) depends on the type of dosimetry system and its evaluation procedure. We can check both the intensity and distribution of each field as the required pretreatment verification ...
Moustafa Ahmed +4 more
doaj +1 more source
Resumen: Introducción: El objetivo del estudio fue conocer el manejo de los pacientes con enfermedad pulmonar intersticial difusa (EPID) asociada a enfermedades autoinmunes sistémicas (EAS) en las consultas de neumología especializadas en EPID en el ...
Orlando Acosta Fernández +5 more
doaj +1 more source
Purpose The aim of this work was to evaluate the SunCHECK PerFRACTION, the software for in vivo monitoring using EPID images. Materials/Methods First, the PerFRACTION ability to detect errors was investigated simulating two situations: (1) variation of ...
Samuel Ramalho Avelino +3 more
semanticscholar +1 more source
An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm [PDF]
Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study,
S M Hashemi +8 more
doaj +1 more source
Purpose To investigate intrinsic sensitivity of an electronic portal imaging device (EPID) and the ArcCHECK detector and to use this in assessing their performance in detecting delivery variations for lung SBRT VMAT.
T. Alharthi +3 more
semanticscholar +1 more source
Objectives: This study performed dosimetry studies and secondary cancer risk assessments on using electronic portal imaging device (EPID) and cone beam computed tomography (CBCT) as image guided tools for the early lung cancer patients treated with SBRT.
Yan-Hua Duan ME +12 more
doaj +1 more source
Flexibility and efficiency in a radiotherapy department with different linear accelerators (linacs) can be improved if they are dosimetrically equivalent, and there is no need of plan or patient-specific quality assurance (PSQA) modification.
José Alejandro Rojas-López +1 more
doaj +1 more source
Purpose To find a suitable method for analyzing electronic portal imaging device (EPID) transmission fluence maps for the identification of position errors in the in vivo dose monitoring of patients with Graves’ ophthalmopathy (GO).
Guyu Dai +11 more
semanticscholar +1 more source