EPID in vivo dosimetry in RapidArc technique [PDF]
The aim of the study was to estimate the dose at the reference point applying an aSi-EPID device in the course of patient treatment.The method assumes direct proportionality between EPID signal and dose delivered to the patient reference point during the treatment session.
Slosarek, Krzysztof +3 more
openaire +3 more sources
EPID – a useful interfraction QC tool [PDF]
Abstract Biomedical accelerators used in radiotherapy are equipped with detector arrays which are commonly used to obtain the image of patient position during the treatment session. These devices use both kilovolt and megavolt x-ray beams.
Klimas, Aleksandra +9 more
openaire +4 more sources
EPID with Efficient Proof of Non-Revocation
EPID systems are anonymous authentication mechanisms which are standardized by ISO/IEC and massively deployed in Intel processors. They are related to the large family of privacy-preserving signatures but differ in that they provide a very pragmatic way of revoking members.
Sanders, Olivier
openaire +3 more sources
Reporting Clinical Results of EPID-Based Patient-Specific Quality Assurance for Brain Stereotactic Radiosurgery/Radiation Therapy: Demonstrating the Feasibility of Same-Day Stereotactic Radiosurgery via HyperArc Delivery [PDF]
Purpose: Patient-specific quality assurance (PSQA) of complex volumetric modulated arc therapy plans via Electronic portal imaging device (EPID)-based portal dosimetry (PD) is widely adopted by the radiation therapy community.
Damodar Pokhrel, PhD +3 more
doaj +2 more sources
Development of Artificial Intelligence as a Conversion Tool for Cine Electronic Portal Imaging Device Images to Radiotherapy Dosimetry: Preliminary Study [PDF]
Introduction: This research is a preliminary study of the development of Artificial Intelligence (AI) as a conversion tool from the pixel value of Cine a-Si 1000 Electronic Portal Imaging Device (EPID) images to dose.
Muhammad Ramadhan +2 more
doaj +1 more source
Development of an Electronic Portal Imaging Device Dosimetry Method
Support arm backscatter and off-axis effects of an electronic portal imaging device (EPID) are challenging for radiotherapy quality assurance. Aiming at the issue, we proposed a simple yet effective method with correction matrices to rectify backscatter ...
Jun Zhang +4 more
doaj +1 more source
Clinical Experience of Intensity Modulated Radiotherapy Pre-Treatment Quality Assurance for Carcinoma Head and Neck Patients with EPID and IMatriXX in Rural Center [PDF]
Background: Radiation therapy techniques as Intensity Modulated Radiotherapy (IMRT), rapid arc have been used for treatment of cancer with high accuracy.
M More, V Jain, O P Gurjar
doaj +1 more source
Resumen: Introducción: El objetivo del estudio fue conocer el manejo de los pacientes con enfermedad pulmonar intersticial difusa (EPID) asociada a enfermedades autoinmunes sistémicas (EAS) en las consultas de neumología especializadas en EPID en el ...
Orlando Acosta Fernández +5 more
doaj +1 more source
An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm [PDF]
Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study,
S M Hashemi +8 more
doaj +1 more source