Results 31 to 40 of about 7,410 (208)
The dose delivery verification for a head and neck static intensity modulated radiation therapy (IMRT) case using a scanning liquid ionization chamber electronic portal imaging device (SLIC-EPID) was investigated.
Mohammad Mohammadi, Eva Bezak
doaj +1 more source
PURPOSE:The goal of this study was to investigate the effectiveness of monitoring relevant variations during treatments for electronic portal imaging device (EPID)-based 3D in vivo verification performed using planning CTs.
Yinghui Li +4 more
doaj +1 more source
Radiotherapy is one of common treatment modality for Nasopharyngeal Cancer. The development of intensity modulated radiotherapy (IMRT technique) gives satisfactory results in the nasopharyngeal cancer treatment, both clinically and dosimetry.
SUSI NOFRIDIANITA
doaj +1 more source
EPID-Based Setup Error Correction in Head and Neck Radiotherapy [PDF]
Introduction: This study introduces and evaluates a novel optimized averaging method for Electronic Portal Imaging Device (EPID)-based setup corrections, comparing it with conventional approaches.
Mohamad Pursamimi +5 more
doaj +1 more source
Dose calibration of EPIDs for segmented IMRT dosimetry [PDF]
The purpose of this study was to investigate the dose response of amorphous silicon (a‐Si) electronic portal imaging devices (EPIDs) under different acquisition settings for both open jaw defined fields and segmented intensity‐modulated radiation therapy (IMRT) fields. Four different EPIDs were used.
Deshpande, S +4 more
openaire +3 more sources
Contrast enhancement of EPID images via difference imaging : a feasibility study
In this study, the feasibility of difference imaging for improving the contrast of electronic portal imaging device (EPID) images is investigated. The difference imaging technique consists of the acquisition of two EPID images (with and without the ...
Khoei, Shadi +9 more
core +1 more source
Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT).
Henzen, Dominik +15 more
core +1 more source
Abstract Numerous studies have been conducted to determine the performance of formulas for calculating crack width and spacing in reinforced concrete structures. Generally, these studies pay limited attention to the application areas of those formulas and how to compare different representations of the crack width and spacing.
Anton van der Esch +2 more
wiley +1 more source
In vivo dosimetry is widely used for patient specific dose evaluation and treatment verification in external beam radiation therapy (EBRT). There is a growing interest in using an electronic portal imaging device (EPID) for in vivo dosimetry, by ...
NC DOCKS at East Carolina University +1 more
core
A Review of the Australian MRI Linac Program: From Pie in the Sky to Research Milestone
ABSTRACT The Australian Magnetic Resonance Imaging (MRI) Linear Accelerator program (MRI linac) was a major research project that aimed to build and test a unique MRI linac prototype for cancer treatment. It aimed to improve radiotherapy anatomical targeting and explore physiological targeting. The purpose of this report is to summarise the development
Michael Bernard Barton +10 more