Results 151 to 160 of about 189,870 (274)

Tailoring Piezoelectric Nanogenerators and Microdevices for Cellular Excitation: Impact of Size and Morphology

open access: yesAdvanced Science, Volume 12, Issue 24, June 26, 2025.
Piezoelectric microdevices, composed of ZnO nanosheets acting as nanogenerators and grown on silicon microparticles, are designed and fabricated to deliver precise electrical cell stimulation. This study optimizes nanosheet growth and microparticle size to enhance electrical cell activation performance while minimizing cellular internalization.
Laura Lefaix   +4 more
wiley   +1 more source

Wearable Hyperspectral Photoplethysmography Allows Continuous Monitoring of Exercise‐Induced Hypertension

open access: yesAdvanced Science, Volume 12, Issue 22, June 12, 2025.
A wearable hyperspectral photoplethysmography (HS‐PPG) is reported for continuous blood pressure (BP) monitoring. The HS‐PPG module integrates an ultrathin double‐folded solid immersion grating microspectrometer (DFSIG‐µSPEC), achieving a high spectral resolution of 3.4 nm.
Jung‐Woo Park   +8 more
wiley   +1 more source

Solution‐Processable Van Der Waals Heterojunctions on Silicon for Self‐Powered Photodetectors with High Responsivity and Detectivity

open access: yesAdvanced Science, Volume 12, Issue 23, June 20, 2025.
This work reports an all‐solution processable fabrication approach for fabricating Ti3C2Tx/Cu3(HHTP)2/n‐Si heterojunction as self‐powered photodetectors through the consecutive spray coating a Cu3(HHTP)2 and Ti3C2Tx thin films on n‐type silicon surface, as formed self‐supplied photodetector reveals exceptional responsivity and detectivity.
Yuansheng Ge   +5 more
wiley   +1 more source

A Single‐Stage Differential Amplifier Using Organic Electrochemical Transistors

open access: yesAdvanced Electronic Materials, Volume 11, Issue 9, June 2025.
A three‐transistor differential amplifier using depletion‐mode organic electrochemical transistors is implemented that offers a common‐mode rejection ratio of up to ≈20 dB. Compared to a Wheatstone bridge amplifier, ECG recordings with this amplifier showed improved signal‐to‐noise ratio, gain, and power consumption.
Farnaz Fahimi Hanzaee   +6 more
wiley   +1 more source

Wearable PZT Piezoelectric Sensor Device for Accurate Arterial Pressure Pulse Waveform Measurement

open access: yesAdvanced Electronic Materials, Volume 11, Issue 9, June 2025.
This work presents a wearable device for the non‐invasive measurement of radial arterial pressure pulse waveforms, incorporating a highly sensitive flexible Lead Zirconate Titanate (PZT) piezoelectric sensor and an optimized tightness‐free attachment method to maximize the sensitivity.
Minyu Li   +3 more
wiley   +1 more source

Polydopamine‐Assisted Electroless Deposition of Magnetic Functional Coatings for 3D‐Printed Microrobots

open access: yesAdvanced Intelligent Systems, Volume 7, Issue 6, June 2025.
A polydopamine (PDA)‐assisted electroless deposition method enables the solution‐based conformal coating of 3D‐printed microstructures with superparamagnetic nickel thin films. This multilayer magnetic coating is implemented and demonstrated in three magnetic microrobot archetypes, including arbitrarily shaped active particles, microrollers, and ...
Shuo Zhang   +6 more
wiley   +1 more source

Metabolically Engineered Extracellular Vesicles Released From a Composite Hydrogel Delivery System Regulate the Microenvironment for Periprosthetic Osteolysis Treatment

open access: yesJournal of Extracellular Vesicles, Volume 14, Issue 6, June 2025.
ABSTRACT Despite remarkable progress in total joint arthroplasty, aseptic loosening of titanium (Ti) alloy persists as a critical clinical challenge due to the poor wear resistance and biological inertness of such implants. Targeting of inflammatory osteolysis and remodelling of the osseointegration environment represent promising therapeutic ...
Chenchen Wang   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy