Extended depth of focus imaging with birefringent plate
In this paper we present a simple approach to obtain extended depth of field for any optical imaging system just by adding a birefringent plate between the lens and the detector. The width of the plate is properly designed such that one polarization state contains in-focus near field information while the other polarization state contains in-focus far ...
Zeev, Zalevsky, Shai, Ben-Yaish
openaire +2 more sources
Double extended depth-of-focus image projection
Double extended depth of focus image projection. In the first two planes, at 0 and 10 micrometer from the fiber facet, movie M1 is displayed. At 20, 30, and 40 micrometer from the fiber facet, movie M2 is displayed. On the right, a depth scan through the
Hana Stolzova (10818087) +2 more
core +1 more source
Visual discomfort and depth-of-field [PDF]
This research was part funded by the BBSRC and EPSRC.Visual discomfort has been reported for certain visual stimuli and under particular viewing conditions, such as stereoscopic viewing.
Zhang, T. +21 more
core +2 more sources
Extended depth of focus image projection
Top: single-depth image projection at 20 micrometers from the fiber facet, visualised at 20, 40 and 60 microns, and (right) a scan through the entire imaging range.
Hana Stolzova (10818087) +2 more
core +1 more source
PURPOSE: To study the visual outcomes and higher order aberrations in eyes implanted with Hybrid EDOF IOL, particularly in Indian eyes. MATERIALS AND METHODS: This is retrospective case series where subjects aged between 40-65 years and were implanted ...
Vaishal P Kenia +3 more
doaj +1 more source
Visual function, ocular surface integrity and symptomatology of a new extended depth-of-focus and a conventional multifocal contact lens [PDF]
Purpose: To evaluate visual function, ocular surface integrity and dry eye symptoms with an extended depth-of-focus (EDOF) design and a conventional multifocal (MF) contact lens (CL) after 15 days of wear.
García Montero, María +4 more
core +1 more source
Katarzyna Ewa Nowik,1 Kamil Nowik,1 Piotr Kanclerz,2,3 Jacek Paweł Szaflik1 1Department of Ophthalmology, Public Ophthalmic Clinical Hospital (SPKSO), Medical University of Warsaw, Warsaw, Poland; 2Department of Ophthalmology, Hygeia Clinic, Gda ...
Nowik KE +3 more
doaj
Outcomes of mini-monovision with monofocal, enhanced monofocal and extended depth-of-focus intraocular lenses [PDF]
Levy I, Shah RP, Mukhija R, Nanavaty MA.
exaly +2 more sources
Swept source optical coherence tomography Gabor fusion splicing technique for microscopy of thick samples using a deformable mirror [PDF]
We present a swept source optical coherence tomography (OCT) system at 1060 nm equipped with a wavefront sensor at 830 nm and a deformable mirror in a closed-loop adaptive optics (AO) system.
Adrian Bradu +9 more
core +1 more source
Purpose: To characterise the monocular defocus curve profile of the TECNIS PureSee purely refractive extended depth-of-focus (EDOF) intraocular lens (IOL) and quantify the extent of functional vision across vergences in a clinical cataract surgery cohort.
Shibu Varkey +4 more
doaj +1 more source