Results 191 to 200 of about 2,957,278 (289)

Comparison of radical prostatectomy and external beam radiotherapy in high-risk prostate cancer. [PDF]

open access: yesUrol Ann
Sangthong P   +5 more
europepmc   +1 more source

Comparison of two close‐packing methods for vertex placement in lattice radiotherapy (LRT)

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Background Lattice Radiation Therapy (LRT) is characterized by its 3D‐mouldated spatial dose distribution of vertices inside the lattice volume with high peak‐to‐valley dose ratio (PVDR) for enhancing tumor control and reducing normal tissue toxicity.
Yingjie Song, Pan Ma, Jianrong Dai
wiley   +1 more source

Characterization of Clinical Outcomes for Patients with Relapsed High-Risk Neuroblastoma After Autologous Stem Cell Transplant and External Beam Radiotherapy. [PDF]

open access: yesCancers (Basel)
Lin M   +22 more
europepmc   +1 more source

Automated offline adaptive radiotherapy through CBCT imaging: A multidimensional feasibility study of hypersight and iterative CBCT

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Background Offline adaptive radiotherapy (OffART) offers potential dosimetric and clinical advantages by adjusting planned dosimetry in response to systematic patient changes throughout treatment, however implementation is associated with an increased labor burden.
Ben R. Archibald‐Heeren   +7 more
wiley   +1 more source

The role of external-beam radiotherapy for differentiated thyroid cancer. [PDF]

open access: yesJpn J Clin Oncol
Kawamoto T   +3 more
europepmc   +1 more source

Dosimetric impact of baseline shift plan in a magnetic resonance linear accelerator according to target motion and plan characteristics

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Purpose In this study, the dosimetric effect of baseline shift (BLS) in a magnetic resonance linear accelerator was investigated and compared with adapt‐to‐position (ATP), adapt‐to‐shape (ATS), and an uncorrected plan without adaptation. Methods In a simulation dataset consisting of 30 patients (10 prostate, 10 liver, 10 pancreatic), all ...
Shohei Tanaka   +11 more
wiley   +1 more source

Proton arc therapy reduces the dose delivered to circulating blood compared to intensity‐modulated proton therapy for head‐and‐neck cancer

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Background Compared to intensity‐modulated proton therapy (IMPT), proton arc therapy (PAT) has various dosimetric advantages. However, questions have been raised over whether the larger low‐dose bath during PAT may increase radiation‐induced lymphocyte killing, which is correlated with adverse clinical outcomes.
Sebastian Tattenberg   +4 more
wiley   +1 more source

Vision and implementation for the first U.S. carbon ion therapy center part II: Design philosophy and clinical implementation

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract The anticipated clinical demand for carbon ion radiotherapy (CIRT) in the United States is expected to include a substantial proportion of clinically complex disease sites that require accurate, highly conformal, and adaptive treatment. These clinical needs, together with the unique physical and biological characteristics of carbon ion beams ...
Xiaoying Liang, Chris J Beltran
wiley   +1 more source

Home - About - Disclaimer - Privacy