Results 71 to 80 of about 10,495 (180)
SUMMARY A 17‐year‐old, 24‐kg, female greater rhea (Rhea americana) presented with an acute onset of left wing droop. Clinical examination and radiographs revealed an open, simple, displaced, short‐oblique diaphyseal fracture of the distal third of the left humerus.
Pierre Huberdeau +6 more
wiley +1 more source
Objectives: The Ilizarov mini-fixator, an external fixator developed for digits, has a structure different from that of general unilateral external fixators.
Reiji Nishimura +6 more
doaj
Aim: To present the functional and radiological results and evaluate the effectiveness of a computer-assisted external fixator (spider frame) in patients with lower extremity shortness and deformity.
Tekin Ali Çağrı +7 more
doaj +1 more source
This paper presents the development and experimental verification of a generative CAD/FEM model of an external bone fixation device. The generative CAD model is based on the development of a parameterized skeleton algorithm and sub-algorithms for ...
Elmedin Mešić +4 more
doaj
A New Mini External Fixator (MEF) for transverse patellar fractures was developed. A model patella and the system develop ed by Weber were used to test and compare its stabylity with the conventional cerclage techniques. \nMagnus on s technique, standart
E. Yesiller +3 more
doaj
Ligamentotaxis for comminuted fracture of capitate: a case report
【Abstract】 We present the technical report for treatment of comminuted fracture of the capitate with ligamentotaxis. The base of third metacarpal was found to be fractured with comminution of the capitate.
Kumar Ashok +3 more
doaj
Background Although the specific relationship between the stress changes in the external fixator during tibial fracture treatment and the bone healing process remains unclear, it is believed that stress variations in the external fixator scaffold can, to
Xuehai Jia +7 more
doaj +1 more source
Femur lengthening with monoplanar external fixator associated with locked intramedullary nail
OBJECTIVE: This study aimed to demonstrate that the lengthening technique of an external fixator associated with locked intramedullary nail is an efficient method that decreases the duration of the external fixation and improves the rehabilitation ...
Henrique Paradella Alvachian Fernandes +3 more
doaj +1 more source
Background. Modular external fixations used in the Philippines are manufactured abroad, leading to high costs and limited availability, making them unaffordable for most Filipino patients. The reliability of some external fixators is limited because not
Maria Patricia Valdez +2 more
doaj +1 more source
Pain and Satisfaction Levels upon Removal of External Fixator at an Outpatient Facility
Objective To quantify the levels of satisfaction and pain of patients submitted to external fixation removal without anesthesia at an outpatient facility.
Vitor Luis Pereira +5 more
doaj +1 more source

