Confining reinforcement for concrete columns have been standardized in building standards ACI 318-11 and SNI 03-2847-2013. The observation of building collapse by earthquake normally caused by malfunction of the building columns as bearing elements.
Hardjasaputra Harianto +3 more
doaj +1 more source
Effective axial strength of laterally strengthened RC pier heads with post‐tensioning method
Abstract This study investigates the structural performance enhancement of reinforced concrete (RC) pier heads laterally strengthened with unbonded post‐tensioning (PT) to accommodate increased design loads following a deck replacement of an existing railway bridge.
Yujae Seo +3 more
wiley +1 more source
Flexural behavior of precast prestressed slabs with embedded building service systems
Abstract Dry‐assembled precast concrete construction is rapidly spreading in many parts of the world due to the several advantages offered by industrialized construction. In order to speed up not only the assemblage of the structure, but also the full integrated building process, engineering systems (mechanical–electrical–plumbing) may be prefabricated
Bruno Dal Lago, Aleksei Abramov
wiley +1 more source
Abstract Several test methods have been proposed in the literature for measuring the level of residual prestress, most of them involving either semi‐ or fully destructive techniques for local measurements which could be highly sensitive to boundary conditions and execution details.
Giuseppe Zarrella +2 more
wiley +1 more source
Abstract This paper presents a regression‐based methodology to estimate the Torsional Stiffness Reduction Factor (TSRF) of reinforced concrete beams under combined torsion and shear. A numerical database of 6816 samples was generated using the Combined Action Softened Truss Model (CA‐STM) implemented in Python, considering design guidelines prescribed ...
Khrys K. S. Medeiros +2 more
wiley +1 more source
Evaluating structural resistance and updating modeling uncertainties through testing
Abstract The aging of infrastructure necessitates a robust and rational methodology for the assessment of existing structures. Design codes provide general models which cover different design scenarios and are thus overly conservative. Also, such design approaches lack field data and, if applied directly to existing works, often lead to unnecessarily ...
Miguel Fernández Ruiz +4 more
wiley +1 more source
The BH 25 steel truss railway bridge in Garut, Indonesia, exhibited a deviation from its intended camber during construction, raising concerns regarding its structural performance.
S. Sumargo, M. Oesman, Fachmi Fadli
semanticscholar +1 more source
Abstract Dry joints are widely used in precast segmental bridge construction because they simplify assembly and accelerate erection. Incorporating fasteners crossing flat dry joints represents an innovative configuration for this type of connection.
Rogelio Franco Segarra +3 more
wiley +1 more source
Behavior of arch composite beam: Experimental and numerical investigation
The behavior of arch composite beams prestressed with external tendons is experimentally and numerically investigated in this study, combining the structural efficiency of arch geometry, composite action, and external prestressing.
Abdelrahim Sabsabi +3 more
doaj +1 more source
Experimental assessment of column rectangularity in flat‐slab slab–column connections
Abstract This paper presents an experimental investigation of the punching shear behavior of seven 3.00 m × 3.00 m × 0.20 m flat slabs without shear reinforcement, supported by internal rectangular columns. The column side lengths were varied to obtain aspect ratios, cmax/cmin, from 1.67 to 4.00, while the flexural reinforcement and overall slab ...
Liana de Lucca Jardim Borges +5 more
wiley +1 more source