Results 81 to 90 of about 2,361,973 (213)
Application of external prestressing on the rehabilitation of reinforced concrete beams
Concrete structure experiencing any form of distress due to multiple reasons; need remedial, strengthening, and rehabilitation measures, if the structure is to attain serviceability and strength requirements of different elements.
Ali K. Al-Asadi
semanticscholar +1 more source
Punching Shear Behavior of Externally Prestressed Concrete Slabs
The use of externally post-tensioned fiber-reinforced concrete decks in highway bridge structures is seen as a viable option in the move toward the design and construction of high-performance structures. However, with the thin unreinforced deck slabs that may result, punching shear is a potential concern.
Mostafaei, H. +3 more
openaire +2 more sources
One innovative and effective technique to enhance the compression response of concrete-filled steel tube (CFST) columns is the compression of the fresh concrete, which actively confines the concrete core by prestressed steel tubes.
Manouchehr Nemati +5 more
doaj +1 more source
To investigate the reinforcing effect of externally prestressed carbon-fiber-reinforced polymer (CFRP) tendons on the shear performance of reinforced concrete beams, a set of model tests was designed.
Hetao Qi +3 more
doaj +1 more source
Basalt fiber reinforced polymer (BFRP) is investigated as a corrosion-resistant alternative for conventional prestressing steel wires in prestressed concrete cylinder pipes (PCCPs).
Jun Li +6 more
doaj +1 more source
To investigate the influence of external prestressing with carbon fiber-reinforced polymer (CFRP) tendons on the flexural and shear performance of reinforced concrete beams, a total of six simply supported beams with a length of 3.5 m and two two-span ...
Zhuang Wang +3 more
doaj +1 more source
Experiments with Externally Prestressed Continuous Composite Girders
Steel-concrete composite girders have attractive potentials when applied in bridge construction. The serviceability performance of continuous composite girders is becoming more and more a deterministic parameter in the design of this type of structures ...
M. Safan, A. Kohoutková
doaj
Mechanical behavior of single concrete frame strengthened with externally prestressed cables. [PDF]
Gao X, Shang J, Song Y.
europepmc +1 more source
Study on prestress loss and safety performance of retard-bonded prestressed cast-in-place piles. [PDF]
Zhu W, Yang X, Zhou H, Yang J, Yao X.
europepmc +1 more source
Study on Damage Evolution and Mechanical Performance of PCCP Before and After Internal Steel-Cylinder Repair Under Multiple Broken-Wire Conditions. [PDF]
Si J, Wang G, Zheng Y, He J, Wang R.
europepmc +1 more source