Results 51 to 60 of about 2,984 (162)
Abstract Objectives In spite of the introduction of automated systems for urinary sediment analysis, microscopy examination remains the gold standard, and it is more than ever important to perform it with a good and reliable quality.
Secchiero S. +4 more
openaire +2 more sources
Abstract Introduction von Willebrand disease (VWD) is a prevalent bleeding disorder resulting from deficiencies and/or defects in von Willebrand factor (VWF). Accurately diagnosing VWD, particularly distinguishing between qualitative defects (types 2A, 2B, 2 M, and 2N) and quantitative defects (types 1 and 3), poses challenges that have significant ...
Emmanuel J. Favaloro +4 more
wiley +1 more source
Background Serum tumor markers such as carcinoembryonic antigen (CEA), alpha-fetoprotein (AFP), and prostate-specific antigen (PSA) are crucial to clinical decision-making based on defined medical thresholds. However, significant inter-method variability
Jong Do Seo +2 more
doaj +1 more source
BackgroundThis study aimed to assess the comparability among assays using freshly frozen human sera and external quality assessment (EQA) data in China.MethodsTwenty-nine serum samples and two commercial EQA materials, obtained from the National Center ...
Shunli Zhang +16 more
doaj +1 more source
UK recommendations for Ki‐67 immunohistochemical staining and interpretation in breast cancer
Where possible, a validated digital imaging system should be utilized. If this is not available, then intermediate scores (5%–30%) should be thoroughly assessed using the Ki‐67 International Working Group guidance. Difficult cases should be double scored.
Abeer M Shaaban +9 more
wiley +1 more source
Background In developing countries, malaria diagnosis relies on microscopy and rapid diagnostic tests. In Senegal, national malaria control program (NMCP) regularly conducts supervisory visits in health services where malaria microscopy is performed.
Mamadou Alpha Diallo +9 more
doaj +1 more source
ABSTRACT Introduction It is recommended to detect lupus anticoagulant (LA) using two phospholipid‐dependent clotting assays, including a LA‐sensitive activated partial‐thromboplastin‐time (aPTT). Among these reagents, Staclot‐LA assay is performed on a mixture of test and normal plasma with and without hexagonal phase phospholipids.
V. Siguret +10 more
wiley +1 more source
Results of a worldwide external quality assessment of cfDNA testing in lung Cancer
Background Circulating cell free DNA (cfDNA) testing of plasma for EGFR somatic variants in lung cancer patients is being widely implemented and with any new service, external quality assessment (EQA) is required to ensure patient safety.
Jennifer A. Fairley +10 more
doaj +1 more source
ABSTRACT Introduction Hematological disorders, critical for diagnosis, and monitoring, rely on accurate complete blood count results from automated analyzers, the reliability of which depends on robust quality control (QC). However, the ability of commutability of commercial hematology QC materials (HQCM) to behave like patient samples across different
Bingshuang Ren +7 more
wiley +1 more source
Testing for Non‐Severe Heritable Platelet Function Disorders
ABSTRACT Heritable platelet function disorders (HPFD) are a diverse group of bleeding disorders characterised by a primary qualitative defect in platelet function rather than platelet number. HPFD may be broadly categorised according to the severity of bleeding, with Glanzmann thrombasthenia and Bernard Soulier syndrome classically considered severe ...
Kate Burley +3 more
wiley +1 more source

