Results 61 to 70 of about 1,117,441 (280)

On the Maintenance of Sterility in Eye-Drops

open access: yesJournal of Pharmacy and Pharmacology, 1954
Conclusion and Summary A number of substances were tested against Ps. pyocyanea (Ps. œruginosa) and their bactericidal concentration determined. The quaternary ammonium compounds, although bactericidal, are not recommended because of their effect on the cornea.
M, KLEIN, E G, MILLWOOD, W W, WALTHER
openaire   +2 more sources

Optoelectronic Synaptic Devices Using Molecular Telluride Phase‐Change Inks for Three‐Factor Learning

open access: yesAdvanced Functional Materials, EarlyView.
Optoelectronic synaptic devices based on solution‐processed molecular telluride GST‐225 phase‐change inks are demonstrated for three‐factor learning. A global optical signal broadcast through a silicon waveguide induces non‐volatile conductance updates exclusively in locally electrically flagged memristors.
Kevin Portner   +14 more
wiley   +1 more source

Prescribing trends of glaucoma medication in Korea from 2007 to 2020: A nationwide population-based study.

open access: yesPLoS ONE
PurposeInvestigating long-term trends in glaucoma medication.MethodsAll patients diagnosed with glaucoma and prescribed glaucoma eye drops between 2007 and 2020 in Korea's Health Insurance Review and Assessment Service database participated in this study.
Kyeong Ik Na   +3 more
doaj   +1 more source

Bone‐Inspired Recyclable Composites for Damage‐Tolerant Circular Materials

open access: yesAdvanced Functional Materials, EarlyView.
Bone‐inspired architected composites are developed by combining osteon‐like reinforcements with a recyclable Elium thermoplastic matrix. The hierarchical architecture redirects cracks and promotes energy dissipation, while enabling recovery of intact, aligned, load‐bearing reinforcement units that retain their original stiffness, revealing a route ...
Alessandro Stagni   +4 more
wiley   +1 more source

Autologous serum eye drops for dry eye [PDF]

open access: yes, 2013
=Theoretically, autologous serum eye drops (AS) have a potential advantage over traditional therapies based on the assumption that ASserve not only as a lacrimal substitute to provide lubrication, but also contain other biochemical components mimicking natural tears more closely.
Qing, Pan   +7 more
openaire   +2 more sources

Multistage, Self‐Sensing Artificial Muscles With Coordination From Liquid Crystal Elastomer‐Graphene Composite Fibers

open access: yesAdvanced Functional Materials, EarlyView.
Inspired by skeletal muscles’ precision and endurance, CoilLCE integrates a self‐sensing liquid crystal elastomer/graphene artificial muscle with an embedded Joule‐heating copper coil, enabling closed‐loop multistage actuation with programmable intermediate states (strain accuracy of 2%), and antagonistic coordination (32% total strain). These features
Ziyun Zhang   +9 more
wiley   +1 more source

A Holistic Platform Approach for Developing Robust Pulmonary mRNA Delivery: Integrating Novel Phenolic Acid‐Derived Ionizable Lipids and Device Engineering

open access: yesAdvanced Functional Materials, EarlyView.
An integrated pulmonary mRNA delivery platform combining novel biodegradable syringic acid‐derived ionizable lipids, design‐of‐experiments formulation optimization, and vibrating‐mesh nebulizer engineering enabled stable aerosolization and efficient lung delivery.
Neha Kaushal   +21 more
wiley   +1 more source

Hopping‐Mediated Zero‐Bias Photocharge Retention in Solution‐Processed Van Der Waals Heterostructures

open access: yesAdvanced Functional Materials, EarlyView.
Liquid–liquid interface assembly enables the fabrication of solution‐processed MoS2 and WSe2 centimeter‐scale, nanometer‐thick type‐II heterostructures on paper. Interfacial charge separation and hopping‐limited recombination produce rectification and persistent photocharge retention at zero bias.
Aniello Pelella   +11 more
wiley   +1 more source

Tear drop in Bull's eye

open access: yesIndian Journal of Ophthalmology. Case Reports, 2022
Swapnil Kamble   +4 more
doaj   +1 more source

Mild toxic anterior segment syndrome mimicking delayed onset toxic anterior segment syndrome after cataract surgery

open access: yesIndian Journal of Ophthalmology, 2014
Toxic anterior segment syndrome (TASS) is an acute sterile postoperative anterior segment inflammation that may occur after anterior segment surgery. I report herein a case that developed mild TASS in one eye after bilateral uneventful cataract surgery ...
Su-Na Lee
doaj   +1 more source

Home - About - Disclaimer - Privacy