Results 191 to 200 of about 58,658 (249)

ZIF-8-Based Surface Plasmon Resonance and Fabry-Pérot Sensors for Volatile Organic Compounds. [PDF]

open access: yesSensors (Basel)
Estany-Macià A   +6 more
europepmc   +1 more source
Some of the next articles are maybe not open access.

Related searches:

Multiplex Fabry-Perot interferometer

SPIE Proceedings, 1991
The Fabry-Perot interferometer (FPI) traditionally has been used to examine either small spectral ranges or relatively imple spectra. Recently, however, studies have shown that the FPI can be competitive with the Michelson interferometer ver extended spectral ranges.
P B, Hays, H E, Snell
openaire   +2 more sources

Electrooptical Fabry-Perot Spectroscopy

Applied Optics, 1973
A new method is described that uses an elegtronic imaging tube to record and explore Fabry-Perot fringes. The light intensity distribution of an interference pattern and the Doppler effect of a line can be observed with an exploration time of the order of 1O(-5) sec.
J M, Gagné, J, Bures, N, Laberge
openaire   +3 more sources

Fabry-Perot recycling spectrometer

Applied Optics, 1976
A new type of Fabry-Perot spectrometer has been developed to achieve multichannel operation with recovery of the light that is lost in conventional systems. The light reflected from the interferometer is recycled in a predetermined way using small right angle prisms.
R, Behn, H F, Döbele
openaire   +2 more sources

Jamin Fabry–Perot interferometer

Optics Letters, 2003
A novel type of interferometer was designed and tested experimentally. It combines the advantages of the spatial path separation used in the two-wave polarized Jamin interferometer and the high sensitivity that characterizes the multiwave Fabry-Perot interferometer. Furthermore, when it is sandwiched between crossed polarizers it shows a sensitivity to
Dominique, Chauvat   +4 more
openaire   +2 more sources

Compressible Fabry-Perot refractometer

Applied Optics, 1987
The use of a long, thermally stable Fabry-Perot etalon as a refractometer is considered in detail in this study of the refractive index of air. The etalon consists of two flat plates of fused silica 60 mm in diameter, with a cylindrical spacer made of Zerodur (a polycrystalline glass ceramic of extremely low thermal expansion) 200 mm long.
M, Andersson, L, Eliasson, L R, Pendrill
openaire   +2 more sources

Fabry-Perot Interferometers

Optica Acta: International Journal of Optics, 1986
(1986). Fabry-Perot Interferometers. Optica Acta: International Journal of Optics: Vol. 33, No. 10, pp. 1227-1227.
openaire   +2 more sources

Fabry-Perot Fringe Enhancement

Applied Optics, 1967
The experimental results are presented to show that it is possible to use a Fabry-Perot interferometer to discriminate multifrequency, uniphase gas laser modulation at frequencies less than the laser's doppler bandwidth. This is done by selecting the F.P. mirror spacing to match the laser cavity. Thus, each F.P. mode discriminates the modulation on its
openaire   +2 more sources

Fabry-Perot inversion algorithm

Applied Optics, 1979
An algorithm for regenerating the input spectrum from Fabry-Perot data is derived and a few numerical experiments are presented to show how well it works.
openaire   +2 more sources

Home - About - Disclaimer - Privacy