Results 41 to 50 of about 1,690,218 (338)

Fracture Nasal Bones [PDF]

open access: yes, 2013
Nose is the most prominent part of the face, hence it is likely to be the most common structure to be injured in the face.  Although fractures involving the nasal bones are very common, it is often ignored by the patient.
Thiagarajan, Balasubramanian   +1 more
core   +1 more source

Multimodal Mechanical Testing of Additively Manufactured Ti6Al4V Lattice Structures: Compression, Bending, and Fatigue

open access: yesAdvanced Engineering Materials, EarlyView.
In this experimental study, the mechanical properties of additively manufactured Ti‐6Al‐4V lattice structures of different geometries are characterized using compression, four point bending and fatigue testing. While TPMS designs show superior fatigue resistance, SplitP and Honeycomb lattice structures combine high stiffness and strength. The resulting
Klaus Burkart   +3 more
wiley   +1 more source

‘old foley’s in a new bottle’- USE OF FOLEY’S CATHETER IN ANTERIOR MAXILLARY WALL FRACTURES [PDF]

open access: yes, 2013
Management of comminuted zygomaticomaxillary fractures are is an entity that has always tested the skill of surgeons. A variety of methods have been coined over the years for management of these fractures.
Kothandaraman, Srikamakshi   +2 more
core   +1 more source

Investigation of Laser Ablation and Brush Pre‐Treatments for AlCu Cold Roll Bonding in Oxygen‐Free Conditions

open access: yesAdvanced Engineering Materials, EarlyView.
It is shown that laser ablation pretreatment under oxygen‐free conditions enables copper–aluminium bonding at significantly lower deformation degrees and improved properties compared to mechanical brushing. Laser ablation further increases interface contact area and induces favourable residual stress states and microstructural compatibility ...
Khemais Barienti   +11 more
wiley   +1 more source

Versatility of Bicoronal flap approach in Head and neck surgeries [PDF]

open access: yes, 2012
Bicoronal approach popularised by Tessier is one of the versatile approaches for skulland frontal region (1-6).In this article we present our experience regarding Bicoronal flapapproach in 3 different cases.
Balachandar, Leena   +1 more
core   +1 more source

Facial Fracture Management in Northwest Nigeria

open access: yesJournal of Surgical Technique and Case Report, 2013
Background: Facial fracture is gradually become a public health problem in our community due to the attendant morbidity and mortality. Hence, the aim of this study was to determine the pattern of facial fracture in Dental and Maxillofacial Surgery ...
A. Taiwo   +3 more
semanticscholar   +1 more source

Piezoresistive Monitoring of Carbon Nanomaterial‐Reinforced Epoxy Composites Under Cyclic and Fatigue Loading: A Review

open access: yesAdvanced Engineering Materials, EarlyView.
Carbon nanomaterial‐reinforced epoxy composites exhibit pronounced piezoresistive behavior, enabling intrinsic damage sensing under cyclic and fatigue loading. This review critically compares carbon nanotube and graphene systems, correlating filler content, percolation threshold, and gauge factor with sensing stability and damage evolution.
J. M. Parente   +3 more
wiley   +1 more source

The residual STL volume as a metric to evaluate accuracy and reproducibility of anatomic models for 3D printing: application in the validation of 3D-printable models of maxillofacial bone from reduced radiation dose CT images. [PDF]

open access: yes, 2015
BackgroundThe effects of reduced radiation dose CT for the generation of maxillofacial bone STL models for 3D printing is currently unknown. Images of two full-face transplantation patients scanned with non-contrast 320-detector row CT were reconstructed
Cai, Tianrun   +8 more
core   +1 more source

Four‐Point Bending Tests at High Temperatures on Commercial MgO‐C Refractory Bricks with and Without Recyclate Considering Different Carbon Contents

open access: yesAdvanced Engineering Materials, EarlyView.
Four‐point bending tests are conducted in an argon atmosphere on commercial MgO‐C brick grades with and without MgO‐C recyclate from room temperature up to 1300 °C. No detrimental effect of the MgO‐C recyclates on bending strength is found. Instead, a decisive influence of the total carbon content is observed, with lower total carbon contents ...
Alexander Schramm   +5 more
wiley   +1 more source

Cost-based analysis of operative maxillofacial fracture managements

open access: yesTurkish Journal of Plastic Surgery, 2020
Aims: There is no current study presenting a descriptive cost-based analysis of operative maxillofacial fracture managements in Turkey. Therefore, this study attempted to investigate the overall treatment costs of maxillofacial traumas.
Mehmet Altiparmak   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy