Results 61 to 70 of about 20,612 (257)

Simulation of activation and propagation delay during tripolar neural stimulation [PDF]

open access: yes, 1993
Computer simulations were perfonned to investigate the influence of stimulus amplitude on cathodal activation delay, propagation delay and blocking during stimulation with a bipolar cuff electrode.
Goodall, Eleanor V.   +3 more
core   +2 more sources

3D (Bio) Printing Combined Fiber Fabrication Methods for Tissue Engineering Applications: Possibilities and Limitations

open access: yesAdvanced Functional Materials, EarlyView.
Biofabrication aims at providing innovative technologies and tools for the fabrication of tissue‐like constructs for tissue engineering and regenerative medicine applications. By integrating multiple biofabrication technologies, such as 3D (bio) printing with fiber fabrication methods, it would be more realistic to reconstruct native tissue's ...
Waseem Kitana   +2 more
wiley   +1 more source

Effects of series elastic compliance on muscle force summation and the rate of force rise [PDF]

open access: yes, 2016
Compliant tendons permit mechanically unfavourable fascicle dynamics during fixed-end contractions. The purpose of this study was to reduce the effective compliance of tendon and investigate how small reductions in active shortening affect twitch ...
Cresswell, Andrew G.   +2 more
core   +2 more sources

Relationship Between Sprint Performance and Muscle Fascicle Length in Female Sprinters.

open access: yesJournal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science, 2001
The purpose of this study was to investigate the relationship between sprint performance and architectural characteristics of leg muscles in 26 female 100-m sprinters. Pennation angle and muscle thickness of the vastus lateralis (VL) and gastrocnemius medialis (GM) and lateralis (GL) muscles were measured by B-mode ultrasonography, and fascicle length ...
T, Abe   +3 more
openaire   +3 more sources

From In‐Silico Optimized Microfabrication to Experimental Validation: Engineering a Tridimensional Epi‐Intraneural Interface

open access: yesAdvanced Functional Materials, EarlyView.
An epi‐intraneural interface is developed through in silico optimization and a novel tridimensional microfabrication pipeline. The device integrates penetrating and epineural contacts on a flexible substrate. Mechanical, electrochemical, and in vivo testing in rat and pig reveal robust implantation, low‐threshold activation, and site‐dependent ...
Federico Ciotti   +14 more
wiley   +1 more source

Muscle Architectural and Functional Adaptations Following 12-Weeks of Stretching in Adolescent Female Athletes

open access: yesFrontiers in Physiology, 2021
This study examined the effects of high-volume static stretching training on gastrocnemius muscle architecture, ankle angle and jump height in 21 female adolescent volleyball players.
Ioli Panidi   +6 more
doaj   +1 more source

Decellularized Extracellular Matrix (dECM) in Tendon Regeneration: A Comprehensive Review

open access: yesAdvanced Healthcare Materials, EarlyView.
Decellularized Extracellular Matrix (dECM) offers a promising solution by replicating the native tendon microenvironment and promoting regeneration. This review highlights advances in the decellularization methods, as well as their integration with emerging technologies and translational progress in tendon tissue engineering.
Kumaresan Sakthiabirami   +4 more
wiley   +1 more source

Smart Catheters for Diagnosis, Monitoring, and Therapy

open access: yesAdvanced Healthcare Materials, EarlyView.
This study presents a comprehensive review of smart catheters, an emerging class of medical devices that integrate embedded sensors, robotics, and communication systems, offering increased functionality and complexity to enable real‐time health monitoring, diagnostics, and treatment. Abstract This review explores smart catheters as an emerging class of
Azra Yaprak Tarman   +12 more
wiley   +1 more source

Ultra‐Thin Soft Pneumatic Actuation for Minimally Invasive Neural Interfacing

open access: yesAdvanced Materials Technologies, EarlyView.
Parylene C is a common polymer in bioelectronics, favored for its biological and chemical inertness. However, this makes bonding layers of Parylene C together very challenging. Here it is a laser to selectively weld layers of Parylene C to create high‐pressure fluidic actuation devices.
Lawrence Coles   +4 more
wiley   +1 more source

Wearable and Implantable Devices for Continuous Monitoring of Muscle Physiological Activity: A Review

open access: yesAdvanced Science, EarlyView.
Recent advances in materials and device engineering enable continuous, real‐time monitoring of muscle activity via wearable and implantable systems. This review critically summarizes emerging technologies for tracking electrophysiological, biomechanical, and oxygenation signals, outlines fundamental principles, and highlights key challenges and ...
Zhengwei Liao   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy