Results 191 to 200 of about 174,013 (259)
Evolution of OLED Lamination Technology With Development of Display Form Factors
This review evaluates the evolution of organic light‐emitting diode (OLED) lamination technologies alongside advancing display form factors. It contrasts optically clear adhesives and resins, highlighting uniformity control for rigid screens, bubble‐free optimization for bended architectures, and visible‐light curing for foldable layers.
Kwan‐Young Han, Ji‐Hoon Park
wiley +1 more source
Nature‐Derived Chitosan Biopolymer: A Promising Candidate for Sustainable Electronics
In the creation of environmentally friendly devices, nature‐derived chitosan biopolymer is a promising contender for sustainable electronic research. It can be utilized to create more ecologically friendly scalable gadgets and has a variety of uses in different active layers of electronics.
Joshua McDonald +3 more
wiley +1 more source
Advanced Manufacturing of Composite‐Based Systems for Energy Applications
Advanced manufacturing enables the integration of polymers, ceramics, metal oxides, and composites into architected microstructures with tailored transport pathways. By coupling material selection, manufacturing strategy, and structural design, multifunctional energy systems can simultaneously improve electrochemical performance, thermal management ...
Sri Vaishnavi Thummalapalli +13 more
wiley +1 more source
Multifunctional Adhesive Hydrogel for Rapid Cardiac Hemostasis and Antibacterial Protection
A multifunctional polyacrylamide/gelatin/tannic acid hydrogel (PGT) is presented for rapid cardiac hemostasis under wet, dynamic conditions. Surface tannic acid coating enables instantaneous wet adhesion, accelerates coagulation, and confers antibacterial activity within a single platform.
Seoha Kim +5 more
wiley +1 more source
This article presents dielectric elastomer switch (DES) materials, based on composite thin films. Alignment of graphite flakes due to their physical confinement within the thin films lead to much stronger piezoresistive responses than bulk composites, while their durability exceeds that of conventional liquid‐based DES materials.
Lingyu Liu +3 more
wiley +1 more source
3D Printing of Soft Robotic Systems: Advances in Fabrication Strategies and Future Trends
Collectively, this review systematically examines 3D‐printed soft robotics, encompassing material selections, function integration, and manufacturing methodologies. Meanwhile, fabrication strategies are analyzed in order of increasing complexity, highlighting persistent challenges with proposed solutions.
Changjiang Liu +5 more
wiley +1 more source
Here, we present a textile, wearable capacitive interface enabling multidirectional remote control by dynamically modulating electrode overlap and spacing via a freely gliding upper electrode. A forearm‐mounted prototype drives robotic and media tasks with 12–15 ms latency, maintains < 0.8% drift after 500 cycles, and remains stably functional at 90 ...
Cagatay Gumus +8 more
wiley +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Journal of Applied Mechanics, Transactions ASME, 1945
Abstract The phenomenon of cumulative damage under repeated loads was assumed to be related to the net work absorbed by a specimen. The number of loading cycles applied expressed as a percentage of the number to failure at a given stress level would be the proportion of useful life expended.
exaly +2 more sources
Abstract The phenomenon of cumulative damage under repeated loads was assumed to be related to the net work absorbed by a specimen. The number of loading cycles applied expressed as a percentage of the number to failure at a given stress level would be the proportion of useful life expended.
exaly +2 more sources
Study of fatigue damage to the cochlea
Computer Methods in Biomechanics and Biomedical Engineering, 2023In order to explore the hearing loss resulting from exposure to continuous or intermittent loud noise. A three-dimensional liquid-solid coupling finite element model of spiral cochlea was established. The reliability of the model was verified, and the stress and amplitude of the basilar membrane of the pivotal structure in cochlea were analyzed.
Lei, Gao +5 more
openaire +2 more sources
Microprocessors and Microsystems, 1980
Abstract The instrument described is a battery operated fatigue damage indicator, designed for continuous field use, attached permanently to the structure being monitored. It is unique in its use of a CMOS microprocessor and continuous LCD display and uses a new algorithm which is a reformulation of an existing fatigue analysis technique so as to ...
Ian R. Whitworth, J. Thickpenny
openaire +1 more source
Abstract The instrument described is a battery operated fatigue damage indicator, designed for continuous field use, attached permanently to the structure being monitored. It is unique in its use of a CMOS microprocessor and continuous LCD display and uses a new algorithm which is a reformulation of an existing fatigue analysis technique so as to ...
Ian R. Whitworth, J. Thickpenny
openaire +1 more source