Analytical Optimal Currents for Multiphase PMSMs Under Fault Conditions and Saturation [PDF]
An original analytical expression is presented in this paper to obtain optimal currents minimizing the copper losses of a multi-phase Permanent Magnet Synchronous Motor (PMSM) under fault conditions.
FLIELLER, Damien +3 more
core +5 more sources
Fault direction identification for wind power integration system
Traditional directional relays of AC transmission lines are usually based on 50 Hz information in frequency domain in China. However, this conventional approach cannot provide the correct fault direction for the lines connected to wind farm because of ...
Yu Chen +5 more
doaj +1 more source
Influence Analysis of Current Limiting Reactor on Pole-to-Pole Short Circuit Fault in DC Distribution System [PDF]
With the development of power electronic technology, flexible DC distribution system has gradually become a research hotspot. Pole-to-pole short circuit fault is the most serious fault type in DC distribution system. When pole-to-pole short circuit fault
Wang Zhenyu +5 more
doaj +1 more source
Implications of fault current limitation for electrical distribution networks [PDF]
This paper explores the potential future need for fault current limitation in the UK's power system, and some of the technical implications of this change.
Blair, S.M. +5 more
core +1 more source
Utility encounters situations like when one out of two power transformers in the substation requires maintenance and only one transformer remains in operation.
A B M Shafiul Azam +3 more
doaj +1 more source
Multiple-fault detection methodology based on vibration and current analysis applied to bearings in induction motors and gearboxes on the kinematic chain [PDF]
© 2016 Juan Jose Saucedo-Dorantes et al. Gearboxes and induction motors are important components in industrial applications and their monitoring condition is critical in the industrial sector so as to reduce costs and maintenance downtimes.
Delgado Prieto, Miquel +4 more
core +2 more sources
The article proposes a mechanical DC circuit breaker (CB) based on a series LC circuit. It requires two switches (a fast disconnector and an AC circuit breaker), an inductor and a capacitor, and therefore the cost is expected to be low.
Dragan Jovcic
doaj +1 more source
Magneto-Thermo-Structural Analysis of Power Transformers under Inrush and Short Circuit Conditions
The main equipment responsible for connection and transmission of electric power from generating centers to consumers are power transformers. This type of equipment is subject to various types of faults that can affect its components, in some cases also ...
Antonio Roniel Marques de Sousa +4 more
doaj +1 more source
The 110 V lead-acid battery pack is widely used as the DC power supply for the load control of power plants. If the low-voltage DC circuit breaker (LVDCCB) at the DC side of its charging device cannot operate in time when the fault current is flowing in ...
Fang Yao +3 more
doaj +1 more source
The contribution current of an inverter-interfaced distributed generator unit during a fault is one of the significant challenges for two modes: grid-connected and isolated AC microgrid.
Mahmoud Aref +5 more
doaj +1 more source