Results 41 to 50 of about 792,011 (298)

Analysis of DC offset in fault current caused by machines in a medium voltage distribution network

open access: yesThe Journal of Engineering, 2019
This study presents a study on the time when the short-circuit fault current in an MV distribution network will cross the zero point in the presence of DC offset affected by the local synchronous and/or induction machines.
Erfan Bashar   +6 more
doaj   +1 more source

Cognitive Functioning in Vorinostat‐Treated Pediatric and Young Adult Patients Over the First 180 Days After Hematopoietic Stem Cell Transplant

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Purpose Cognitive and psychological difficulties could negatively interfere with treatment adherence and quality of life before and after hematopoietic stem cell transplant (HSCT). Methods to mitigate these changes may have positive effects on treatment success.
Kristen L. Votruba   +11 more
wiley   +1 more source

Bidirectional solid current-limiter for HVDC grids

open access: yesThe Journal of Engineering, 2019
High-voltage direct current (HVDC) grids have been assumed as a promising technology for its advantages in accommodation and integration of large-scale renewable energy.
Jiantao Li   +4 more
doaj   +1 more source

A Fault-Tolerant T-Type Multilevel Inverter Topology With Increased Overload Capability and Soft-Switching Characteristics [PDF]

open access: yes, 2017
he performance of a novel three-phase four-leg fault-tolerant T-type inverter topology is introduced in this paper. This inverter topology provides a fault-tolerant solution to any open-circuit and certain short-circuit switching faults in the power ...
Demerdash, Nabeel   +4 more
core   +2 more sources

MYCN Amplification in RB1‐Inactivated Retinoblastoma: Association With High‐Risk Features

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background MYCN amplification occurs in a subset of retinoblastoma cases, both with and without RB1 inactivation. It has been suggested that retinoblastomas with MYCN amplification represent a distinct entity with more aggressive clinical behavior.
Kyriaki Papaioannou   +9 more
wiley   +1 more source

Multiple ETS family transcription factors bind mutant p53 via distinct interaction regions

open access: yesFEBS Letters, EarlyView.
Mutant p53 gain‐of‐function is thought to be mediated by interaction with other transcription factors. We identify multiple ETS transcription factors that can bind mutant p53 and found that this interaction can be promoted by a PXXPP motif. ETS proteins that strongly bound mutant p53 were upregulated in ovarian cancer compared to ETS proteins that ...
Stephanie A. Metcalf   +6 more
wiley   +1 more source

Apparatus including a plurality of spaced transformers for locating short circuits in cables [PDF]

open access: yes, 1978
A cable fault locator is described for sensing faults such as short circuits in power cables. The apparatus includes a plurality of current transformers strategically located along a cable.
Cason, R. L., Mcstay, J. J.
core   +1 more source

Inhibiting stearoyl‐CoA desaturase suppresses bone metastatic prostate cancer by modulating cellular stress, mTOR signaling, and DNA damage response

open access: yesFEBS Letters, EarlyView.
Bone metastasis in prostate cancer (PCa) patients is a clinical hurdle due to the poor understanding of the supportive bone microenvironment. Here, we identify stearoyl‐CoA desaturase (SCD) as a tumor‐promoting enzyme and potential therapeutic target in bone metastatic PCa.
Alexis Wilson   +7 more
wiley   +1 more source

An adaptive zero-sequence current protection scheme for distribution networks based on iterative fault current calculation of IIDGs

open access: yesZhejiang dianli
Due to the inherent output fluctuations of inverter-interfaced distributed generators (IIDGs), the fault characteristics of distribution networks have changed, posing challenges for relay protection setting.
LI Juan   +3 more
doaj   +1 more source

Fault location for MMC–MTDC transmission lines based on least squares-support vector regression

open access: yesThe Journal of Engineering, 2019
The dc transmission line protection plays a crucial role in the secure operation of a multi-terminal modular-multilevel-converter-based high-voltage direct current (MMC–MTDC) system, which is increasingly adopted as a promising option in the power ...
Mingguang Zhang, Heng Wang
doaj   +1 more source

Home - About - Disclaimer - Privacy