Results 11 to 20 of about 580 (262)
The wind energy conversion technology of a Permanent Magnet Synchronous Generator (PMSG) is very promising in renewable power generation. However, the performance of the grid-connected PMSGs is greatly affected by grid disturbances because their stator ...
Kenneth E. Okedu, Kenneth E. Okedu
doaj +1 more source
Doubly fed induction generators (DFIGs) are vulnerable to grid related electrical faults. Standards require DFIGs to be disconnected from the grid unless augmented with a fault ride through (FRT) capability.
Md. Rashidul Islam +5 more
doaj +1 more source
Low voltage ride-through capability improvement methods for DFIG based wind farm
In this paper the low voltage ride-through (LVRT) capability enhancement of the DFIG based wind farm (WF) is accomplished by using of the existing series devices like the new bridge type fault current limiter (NBFCL), new solid-state fault current ...
Md Emrad Hossain
doaj +1 more source
ABSTRAK Integrasi pembangkit listrik energi baru terbarukan ke jaringan listrik yang sudah ada dapat menyebabkan kenaikan arus gangguan, mengakibatkan peralatan proteksi yang ada tidak mampu untuk menangulanginya.
Lauhil Mahfudz Hayusman +2 more
doaj +1 more source
Inductive Fault Current Limiters in VSC-HVDC Systems: A Review
Fast emerging fault current levels in high voltage direct current (HVDC) systems has always been a significant obstacle to building a safer and more reliable grid. Inductive fault current limiters (FCLs), compared with its resistive counterpart, are very
Hang Zhou +3 more
doaj +1 more source
Analytical Modeling of Rotary Electromagnetic Fault Current Limiter
Rotary electromagnetic fault current limiter (FCL) is an emerging technology for limiting fault currents in the power network. The device consists of two movable air-core spherical reactor rings (i.e., inner and outer rings).
Seyed Amin Fazljoo +2 more
doaj +1 more source
Investigation of the Operation of Active Superconducting Fault Current Limiters in Distribution Networks Connected to Microgrids [PDF]
Increasing the penetration level of distributed generation (DG) units in radial power distribution systems can increase the short-circuit level in these networks, which can, in turn, have destructive effects such as exceeding the tolerable current of the
Ahmad Ghafari +3 more
doaj +1 more source
Enhancing Transient Stability of DFIG-Based Wind Turbine Systems Using Deep Learning-Controlled Resistance-Based Fault Current Limiters [PDF]
This research addresses the challenge of grid stability when integrating renewable energy, especially wind power. It focuses on enhancing transient stability in doubly fed induction generator (DFIG) wind energy systems using advanced strategies like ...
Yaoying Wang
doaj +1 more source
Controllable-Dual Bridge Fault Current Limiter for Interconnection Micro-Grids
Different types of fault current limiters (FCLs) have been developed and designed based on non-superconducting DC reactors (NSDRs). This paper proposes a controllable dual-bridge FCL (CDBFCL) based on the NSDR for use in an AC-type micro-grid.
Hossein Shahbabaei Kartijkolaie +4 more
doaj +1 more source
Three-Phase Saturated-Core Fault Current Limiter
The saturated-core fault current limiter (SFCL) is widely used to limit the fault current. However, in the conventional SFCL structure, alternating current (AC) and direct current (DC) coils are wound on different loosely coupled cores.
Haocong Shen +4 more
doaj +1 more source

