Results 31 to 40 of about 580 (262)
DC fault clearance is one of the critical issues for the modular‐multilevel‐converter‐based high voltage direct current (MMC‐HVDC) systems. Employing a hybrid DC circuit breaker (H‐DCCB) to isolate the faulty line is a typical method to achieve fast ...
Pan Duan +3 more
doaj +1 more source
ABSTRACT Pediatric radiation therapy presents unique challenges compared to adult treatments, including those of immobilization, potential need for sedation, and the critical importance of accurate, reproducible positioning. Additionally, heightened attention to imaging doses is necessary to minimize long‐term toxicity in survivors.
Parham Alaei +17 more
wiley +1 more source
DC Fault Current Analyzing, Limiting, and Clearing in DC Microgrid Clusters
A new DC fault current limiter (FCL)-based circuit breaker (CB) for DC microgrid (MG) clusters is proposed in this paper. The analytical expressions of the DC fault current of a bidirectional interlink DC/DC converter in the interconnection line of two ...
Navid Bayati +5 more
doaj +1 more source
ABSTRACT Objectives The association between exposure to dinutuximab beta (DB) and event‐free survival (EFS) or overall survival (OS) of neuroblastoma patients was assessed using data collected during three clinical trials (five cohorts). Methods A systematic review (March 2026) was conducted to identify relevant studies (prospective; registered DB ...
Przemysław Holko +19 more
wiley +1 more source
A Novel Self-Protective Transformer Using a Fault Current Limiter Approach
Transformers are essential components of distribution systems but are vulnerable to fault currents, posing significant challenges for their protection.
Sajjad Agheli +2 more
doaj +1 more source
The half bridge (HB) modular multilevel converter (MMC) technology is considered a breakthrough to mitigate the shortcomings of the conventional voltage source converter (VSC) in high-voltage direct-current (HVDC) grid application.
Ho-Yun Lee +4 more
doaj +1 more source
ABSTRACT Background Survival after relapse in pediatric acute myeloid leukemia (AML) remains poor, highlighting the critical importance of identifying prognostic factors to guide optimal relapse management. Methods We investigated the prognostic impact of multiparameter flow cytometry (MFC) measurable residual disease (MRD) in 188 patients with first ...
Camilla Poulsen +21 more
wiley +1 more source
A bridge type superconducting fault current limiter (SFCL) with simultaneous quench using two high-temperature superconducting (HTSC) elements and two coils was fabricated to analyze the fault current limiting characteristics.
Seok-Cheol Ko, Tae-Hee Han, Sung-Hun Lim
doaj +1 more source
ABSTRACT Background General pediatricians often evaluate hematologic and oncologic presentations before subspecialty consultation, yet the 2025 Accreditation Council for Graduate Medical Education (ACGME) pediatric requirements reduce inpatient pediatric hematology/oncology (PHO) time, raising questions about resident readiness.
Colburn Yu, Rohini Jain
wiley +1 more source
To develop mechanical circuit breaker in high voltage direct current (HVDC) system, a fault current limiter is required. Traditional method to limit DC fault current is to use superconducting technology or power electronic devices, which is quite ...
Jiaxin Yuan +7 more
doaj +1 more source