Results 31 to 40 of about 6,133,186 (147)

Analysis of energy dissipation in resistive superconducting fault-current limiters for optimal power system performance [PDF]

open access: yes, 2011
Fault levels in electrical distribution systems are rising due to the increasing presence of distributed generation, and this rising trend is expected to continue in the future.
Burt, Graeme   +4 more
core   +4 more sources

Transient stability enhancement of steam turbine-based power plant by using improved bridge fault current limiter

open access: yesEngineering Science and Technology, an International Journal, 2023
This paper presents a new bridge Fault Current Limiter (FCL) used for the improvement of the transient stability of steam turbine-based power plants.
Dmitry Baimel
doaj   +1 more source

Investigation of the Operation of Active Superconducting Fault Current Limiters in Distribution Networks Connected to Microgrids [PDF]

open access: yesJournal of Applied Research in Electrical Engineering, 2023
Increasing the penetration level of distributed generation (DG) units in radial power distribution systems can increase the short-circuit level in these networks, which can, in turn, have destructive effects such as exceeding the tolerable current of the
Ahmad Ghafari   +3 more
doaj   +1 more source

DC Fault Current Analyzing, Limiting, and Clearing in DC Microgrid Clusters

open access: yesEnergies, 2021
A new DC fault current limiter (FCL)-based circuit breaker (CB) for DC microgrid (MG) clusters is proposed in this paper. The analytical expressions of the DC fault current of a bidirectional interlink DC/DC converter in the interconnection line of two ...
Navid Bayati   +5 more
doaj   +1 more source

Current–time characteristics of resistive superconducting fault current limiters [PDF]

open access: yes, 2012
Superconducting fault current limiters (SFCLs) may play an important role in power-dense electrical systems. Therefore, it is important to understand the dynamic characteristics of SFCLs.
Burt, Graeme   +2 more
core   +4 more sources

The use of fault current limiter to reduce the operating time of relays [PDF]

open access: yesمجله مدل سازی در مهندسی, 2018
In distribution network with displacement at network level, the fault current does not significantly change and it is not possible to effectively utilize the inverse time over-current relays, since, if the number of primary and backup relays increases ...
Ehsan Khoob   +2 more
doaj   +1 more source

Analysis of influence of a novel inductive fault current limiter on the circuit breaker in 500 kV power system

open access: yesHigh Voltage, 2021
A contribution to the engineering application of a proposed 500 kV fault current limiter (FCL) is presented. A new type of FCL composed of a highly coupled split reactor (HCSR) and fast switches is proposed.
Qiang Tang   +6 more
doaj   +1 more source

Reduction Effect of Semiconductor Type Fault Current Limiter on Interrupting Duty of a Circuit Breaker [PDF]

open access: yes, 2002
Calculations were carried out to study the effect of a semiconductor type of fault current limiter (FCL) upon the interrupting duty imposed on a circuit breaker when a fault occurs at a distance of 1 to 8 km downstream from the load side terminals of the
Calixte, Evenson   +4 more
core   +1 more source

A voltage-clamped bidirectional fault current limiter based on a three-winding coupled inductor for DC power grids

open access: yesInternational Journal of Electrical Power & Energy Systems
The DC fault is a serious challenge to voltage-source-converter-based HVDC (VSC-HVDC) systems, and the fault current limiter (FCL) is one of the key measures to solve the DC fault and reduce the capacity of the DC circuit breaker.
Ziao Yuan   +4 more
doaj   +1 more source

Design guideline of flux-lock type HTS fault current limiter for power system application [PDF]

open access: yes, 2001
We have proposed a “Flux-Lock” type high T, superconducting (HTS) fault current limiter (FCL) composed of the flux-lock reactor with HTS element and the magnetic field coil circuit, In this FCL, the initial limiting current level can be arranged by ...
Shimizu, H., Yokomizu, Y., Matsumura, T.
core   +1 more source

Home - About - Disclaimer - Privacy