Results 111 to 120 of about 1,378 (185)

Optimal Multiple FCLs Allocation Considering DG Penetration in Meshed Network With Multi-Level Voltages

open access: yesIranian Journal of Electrical and Electronic Engineering, 2020
Increasing the short circuit current due to the penetration of distributed generations (DGs) in various voltage levels and meshed topology is a basic problem in power systems.
M. Hosseinpour, J. Sadeh
doaj  

Coordinated Source-Grid fault current limiting strategy in HVDC grids based on fault severity and quantitative limitation demand

open access: yesInternational Journal of Electrical Power & Energy Systems
Reliable fault current limitation is critical in high-voltage direct current (HVDC) grids due to the fast dynamics and low fault tolerance of power electronic equipment, as well as the high cost of DC circuit breakers (DCCBs). To address these challenges,
Yuhong Wang   +5 more
doaj   +1 more source

Electronic fault current limiter based on resonant circuit controlled by power semiconductor devices

open access: yes, 2006
This dissertation presents a study of a resonant fault current limiter (FCL) controlled by power semiconductor devices. Initially the operation of two ideal resonant circuit topologies as fault current limiter are discussed.
Lanes, Matusalém Martins
core  

An effect of fault current limiter to distributed generator shaft torque increase under voltage sag

open access: yes, 2007
Voltage sags originated at the transmission level can have a very adverse effect on distributed generators running at distribution levels. A fault current limiter (FCL) can be an effective means to limit the voltage sag impact.
Tanabe, Takayuki   +7 more
core   +1 more source

Critical Current Determination in High-Quality YBCO Rings for Application in a Fault Current Limiter

open access: yes, 2001
v, 28 p.The first section of this work is an introduction to basic properties of superconductors and the theory of operation of a superconducting fault current limiter (FCL).
Weber, Jonathan M.
core  

IMPACT ON PARALLEL-RESONANCE TYPE FAULT CURRENT LIMITER OPERATING UNDER SEVERAL FAULT CONDITIONS

open access: yes, 2014
Potential fault current levels in power grids is approaching, and may eventually exceed, the short-circuit-current limits of existing protection devices.
Gangadhar, V.; Pursuing M-Tech, Department of Electrical & Electronics Engineering,AIMS College of Engineering, Mummidivarm, East Godavari Dist, Andhra Pradesh, India.   +1 more
core  

非线性变压器理论在高压直流故障电流限制器中的应用研究

open access: yesGaoya dianqi, 2019
高压直流故障电流限制器(fault current limiter,FCL)是先进超导托卡马克装置系统中用于抑制短路电流,保护中性束注入系统的一种类变压器装置。文中从变压器铁心叠片的涡流损耗特性出发,采用分段线性插值的方法对FCL非线性磁滞回线模型进行优化,推导出非线性激磁电阻与电感的并联模型。通过仿真及实验的对比分析,结果表明优化磁滞回线模型仿真波形与试验结果吻合度高,短路电流抑制效果良好。
谢飞, 屈鲁, 金环
doaj  

Home - About - Disclaimer - Privacy