Results 41 to 50 of about 397 (158)
A hybrid h-bridge fault current limiter for HVDC grid protection [PDF]
For half-bridge modular multilevel converter (MMC) based HVDC grids, the fast clearance of DC faults can be achieved by DC circuit breakers (DCCBs). The hybrid fault current limiter (FCL) can be used to assist DCCBs for faster interruption less capacity.
Zhao, Chengyong +9 more
core +1 more source
Transient simulation and analysis for saturated core high temperature superconducting fault current limiter [PDF]
In this paper, the transient performance of a magnetic core fault current limiter (FCL) saturated by high temperature superconducting (HTS) DC bias winding is investigated by using 3-dimensional (3D) field-circuit coupled simulation.
Youguang, G +6 more
core +1 more source
This paper proposes an effective fault management scheme for medium‐voltage direct current (MVDC) networks, which includes a virtual‐impedance‐based fault current limiter (VI‐FCL) on the DC side and a positive‐negative‐sequence (PNS) control scheme on ...
Dongsen Sun +3 more
doaj +1 more source
A Self-Activated Fault Current Limiter for Distribution Network Protection [PDF]
Rapid protection of modern electric networks using fault current limiters (FCLs) is often delayed and limited by the inherent controller, sensor, and power electronic unit delays.
Rouzbehi, K +3 more
core +1 more source
The DC fault is a serious challenge to voltage-source-converter-based HVDC (VSC-HVDC) systems, and the fault current limiter (FCL) is one of the key measures to solve the DC fault and reduce the capacity of the DC circuit breaker.
Ziao Yuan +4 more
doaj +1 more source
OVERCURRENT RELAY COORDINATION IN DISTRIBUTED GENERATION WITH FAULT CURRENT LIMITER [PDF]
The distribution network has many advantages when it is connected to distributed generation (DG). Some problems in coordination of protection devices will occur in the presence of DG, due to change in short circuit level at different points.
Amit A. Chatte (5115593), Amit A. Chatte
core +1 more source
Power system analysis of a resistive HTS fault current limiter [PDF]
This paper investigates the performance of a prototype resistive fault current limiter (FCL) made using a high temperature superconductor (HTS). Its behavior under normal operation and short-circuit conditions in a 6 kV/1 kA power system is analyzed with
Liu, ZY +7 more
core +1 more source
Under unbalanced grid condition, in a Doubly-Fed Induction Generator (DFIG), voltage, current, and flux of the stator become asymmetric. Therefore, active-reactive power and torque will be oscillating.
Ali Akbar Vali +2 more
doaj +1 more source
Data‐Driven Bulldozer Blade Control for Autonomous Terrain Leveling
A simulation‐driven framework for autonomous bulldozer leveling is presented, combining high‐fidelity terramechanics simulation with a neural‐network‐based reduced‐order model. Gradient‐based optimization enables efficient, low‐level blade control that balances leveling quality and operation time.
Harry Zhang +5 more
wiley +1 more source
Operational control and protection implications of fault current limitation in distribution networks [PDF]
Rising short-circuit fault current levels is one of the problems associated with the increased presence of distributed generation (DG) in electrical networks.
Blair, S.M. +3 more
core