Results 61 to 70 of about 397 (158)

Plant‐protein supplementation improves thermoregulatory responses and ameliorates markers of intestinal damage during exercise in the heat

open access: yesExperimental Physiology, EarlyView.
Abstract Exercise in the heat often causes gastrointestinal (GI) disturbances, which can impair performance. Single amino acid supplementation can attenuate gut damage and enhance exercise tolerance; however, the effectiveness of innate amino acid blends from plant‐based proteins remains underexplored.
Robyn Aitkenhead   +4 more
wiley   +1 more source

Placement optimization of Multi-Type fault current limiters based on genetic algorithm

open access: yesGlobal Energy Interconnection, 2021
The fault current limiter (FCL) is an effective measure for improving system stability and suppressing short-circuit fault current. Because of space and economic costs, the optimum placement of FCLs is vital in industrial applications. In this study, two
Guofeng Jin   +4 more
doaj   +1 more source

Control Design for a Power Electronic Based Fault Current Limiter (FCL)

open access: yesRE&PQJ
This paper shows a solution for controlling shortcircuit currents of a power electronic based Fault Current Limiter (FCL). A model for control design of three-phase short-circuit currents will be presented. A way of limiting the maximum aperiodic short-circuit current is derived with special regards to the stability of the entire system.
null C. Hahn   +2 more
openaire   +1 more source

Contralateral Thermal Pain and Naturally Occurring Muscle Pain Have Different Effects on Force Production During a Fixed Perceived Effort Handgrip Task

open access: yesEuropean Journal of Pain, Volume 30, Issue 6, July 2026.
ABSTRACT Background In the presence of pain, performance during imposed workload motor tasks may be maintained at the cost of a higher perceived effort. This study investigated how experimentally induced contralateral thermal pain and naturally occurring muscle pain influence force production during a fixed perceived effort task.
Callum A. O'Malley   +7 more
wiley   +1 more source

A New Fault Current Limiter and its Application in Micro-Grid [PDF]

open access: yes, 2011
In this paper, a new type fault current limiter (FCL) topology is put forward for Micro-Grid (MG) system fault, which mainly consists of limiting inductance, bypass inductance and series compensation capacitors.
Ying Jun Sang, Yuan Yuan Fan
core   +1 more source

Reversal of economic integration: evidence from European Union enlargement

open access: yesThe Scandinavian Journal of Economics, Volume 128, Issue 3, Page 660-685, July 2026.
Abstract Empirical models of trade agreements implicitly assume that withdrawal from a trade agreement has an equal and opposite trade effect as accession (i.e., symmetry). With increasing opposition to international economic cooperation, it becomes urgent to test this assumption.
Hinnerk Gnutzmann   +2 more
wiley   +1 more source

Enhancement of DUBAL Network Operational Performance Using Resistive High Temperature Superconducting Fault Current Limiter

open access: yesEnergies, 2019
Power systems under expansion suffer from escalating fault levels that impact equipment integrity, operational flexibility, and the overall security of the system.
Hamood Naji   +2 more
doaj   +1 more source

Backbone‐Controlled Ion‐Side Chain Accessibility in Conjugated Polymers for Organic Electrochemical Synaptic Transistors

open access: yesAdvanced Functional Materials, Volume 36, Issue 50, 22 June 2026.
Backbone modulation in glycolated conjugated polymers governs ion accessibility to side chains, strengthes anion adsorption, and suppresses back‐diffusion. As the number of thiophene units increases, structural reorganization, retention, and synaptic plasticity are enhanced, leading to improved neuromorphic performance in electrolyte‐gated organic ...
Junho Sung   +10 more
wiley   +1 more source

A novel current-limiting hybrid DC breaker based on thyristors

open access: yesEnergy Reports, 2023
Since the DC current has no zero-crossing in high-voltage and large-capacity DC scenarios, and the low line impedance results in a large growth rate of fault current, the breaking requirements of DC circuit breakers (DCCB) are further increased.
Xinchao Yu   +4 more
doaj   +1 more source

Ferromagnetically Shielded Fault Current Limiter (FS‐FCL) Evaluation in Power Line

open access: yesIET Generation, Transmission & Distribution
ABSTRACT This paper presents a novel ferromagnetically shielded fault current limiter (FS‐FCL) configuration and control strategy for power systems. The proposed system introduces a controlled DC‐reactor design that effectively limits fault currents without significantly affecting the system voltage during normal operation.
Kamran Ghorbanyan, Selim Acar
openaire   +1 more source

Home - About - Disclaimer - Privacy