Results 81 to 90 of about 397 (158)

New Series Resonance Type Fault Current Limiter [PDF]

open access: yes, 2011
This paper proposes a new topology for fault current limiter (FCL) that is based on series LC resonance circuit. The proposed FCL uses a high speed switch to put an inductor in series with a capacitor and make resonance condition between them.
Seyedbehzad Naderi (14745067)   +2 more
core  

Transient stability enhancement of multi-machine power system by parallel resonance type fault current limiter [PDF]

open access: yes, 2015
This paper proposes the parallel resonance type fault current limiter (PRFCL) to enhance the transient stability of multi-machine power systems. The transient stability performance of the parallel resonance type FCL is compared with that of the bridge ...
Mohd. Hasan Ali   +3 more
core   +1 more source

Fault Current Limiter Using Ybco Coated Conductor-the Limiting Factor And Its Recovery Time [PDF]

open access: yes, 2015
A fault current limiter (FCL) based on an arrangement of parallel connected high temperature superconducting tapes constituting a limiter element was designed and tested in 220 V line for a fault current peak between 1 kA to 2 kA.
Baldan C.A.   +3 more
core   +3 more sources

Efficacy and Safety of Automated Insulin Delivery in People With Type 2 Diabetes: A Systematic Review and Meta‐Analysis

open access: yesDiabetes, Obesity and Metabolism, Volume 28, Issue 6, Page 5091-5100, June 2026.
ABSTRACT Aims Studies evaluating automated insulin delivery (AID) in type 2 diabetes are limited in number and often conducted in small cohorts. We aimed to summarize efficacy and safety data through a systematic review and meta‐analysis. Materials and Methods We searched MEDLINE, PubMed, Web of Science, and CENTRAL databases and performed hand ...
Sergio Di Molfetta   +7 more
wiley   +1 more source

The impact of fault current limiter in power system performance [PDF]

open access: yes, 2009
Continues growth of electrical energy demand is resulting in a corresponding increase in the short circuit in power system. Several solutions have been implemented, including the use of Fault Current Limiter (FCL), in order to reduce circuit breakers ...
Mohd. Ariff, Mohd. Aifaa   +1 more
core  

Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter

open access: yesEnergies, 2019
As one of the key technologies to solve the problem of high short-circuit current, the fault current limiter (FCL) has become a research hotspot in China and abroad.
Changfu Chen   +8 more
doaj   +1 more source

Comparative Effectiveness and Future Viability of Flood Control Adaptation Measures Under a Changing Climate and a Declining Population

open access: yesJournal of Flood Risk Management, Volume 19, Issue 2, June 2026.
ABSTRACT Adaptation measures play a crucial role in mitigating the increasing severity of flood disasters driven by climate change. While various strategies are implemented globally, their geographical characteristics and long‐term effectiveness remain uncertain.
Takaya Kaneko   +5 more
wiley   +1 more source

Development of Passive Fault Current Limiter in Parallel Biasing Mode [PDF]

open access: yes, 1999
So far the reported literature on the magnetic fault current limltcr(FCL) arc based on series biasing mode in which the flux due to Hue current flows through the permanent magnet, As a result there ta a high possibility of demagnetization of the ...
80020212   +9 more
core   +4 more sources

Non-controlled fault current limiter to improve fault ride through capability of DFIG-based wind turbine [PDF]

open access: yes, 2016
In this paper, a non-controlled fault current limiter (FCL) is proposed to improve fault ride through capability of doubly fed induction generator (DFIG)-based wind turbine.
Seyedbehzad Naderi (14745067)   +3 more
core   +2 more sources

A Dynamic Multi-Cell FCL to Improve the Fault Ride through Capability of DFIG-Based Wind Farms

open access: yesEnergies, 2020
Endowing wind farms (WFs) with fault ride through (FRT) capability is crucial to their continuous availability under various operating conditions. This paper proposes a dynamic adaptive multi-cell fault current limiter (MCFCL) topology to enhance the FRT
M. R. Shafiee   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy