Results 41 to 50 of about 1,071 (155)
Generating performance of limiting impedance in flat type of fault current limiter with high Tc superconducting plate [PDF]
We have proposed a flat type of the superconducting fault current limiter (FCL) which is a modified version of a magnetic shielding type of the fault current limiter.
13120 +13 more
core +1 more source
Thermal regimes of HTS cylinders operating in devices for fault current limitation
We reveal obstacles related to the application of HTS cylinders in current limiting devices based on the superconducting - normal state transition. It is shown that, at the critical current density achieved presently in bulk materials, and especially in ...
Bock J +15 more
core +1 more source
An enhancing fault current limitation hybrid droop/V-f control for grid-tied four-wire inverters in AC microgrids [PDF]
Microgrid integration and fault protection in complex network scenarios is a coming challenge to be faced with new strategies and solutions. In this context of increasing complexity, this paper describes two specific overload control strategies for four ...
Aguado, Monica +6 more
core +2 more sources
Under unbalanced grid condition, in a Doubly-Fed Induction Generator (DFIG), voltage, current, and flux of the stator become asymmetric. Therefore, active-reactive power and torque will be oscillating.
Ali Akbar Vali +2 more
doaj +1 more source
A Comprehensive Review of Low-Voltage-Ride-Through Methods for Fixed-Speed Wind Power Generators [PDF]
This paper presents a comprehensive review of various techniques employed to enhance the low voltage ride through (LVRT) capability of the fixed-speed induction generators (FSIGs)-based wind turbines (WTs), which has a non-negligible 20% contribution of ...
Guerrero, Josep M. +2 more
core +2 more sources
The Y supersaturation in the [Ba‐Cu(I/II)‐O] transient liquid composition is the driving force toward YBCO nucleation and growth in TLAG. Tuning the initial (Ba:Cu) molar ratio in the ink composition determines the YBCO epitaxial nucleation through supersaturation control.
Lavinia Saltarelli +12 more
wiley +1 more source
Fault Current Limiter optimal sizing considering different Microgrid operational modes using Bat and Cuckoo Search Algorithm [PDF]
Nowadays, the development of smart grids has been the focus of attention due to its advantages for power systems. One of the aspects of smart grids defined by using distributed generation (DG) in a low voltage network is a microgrid (MG).
Ali Asghar Khodadoost Arani +4 more
doaj +1 more source
Data‐Driven Bulldozer Blade Control for Autonomous Terrain Leveling
A simulation‐driven framework for autonomous bulldozer leveling is presented, combining high‐fidelity terramechanics simulation with a neural‐network‐based reduced‐order model. Gradient‐based optimization enables efficient, low‐level blade control that balances leveling quality and operation time.
Harry Zhang +5 more
wiley +1 more source
Impact of increased distributed generation on fault levels and the network equipment [PDF]
Attention towards the development of Distributed Generation (DG) is globally high. UK's concentration is to use sustainable and renewable sources to generate electricity thereby protecting the environment from getting polluted. In this paper, Distributed
Bhavanam, YR, Shahrazad, M
core
Numerous proposed and developed superconducting fault current limiters and self-limiting transformers limit successfully fault currents but do not provide uninterrupted supplying of consumers. A design investigated in the work combines the functions of a
Altov +18 more
core +1 more source

