Results 71 to 80 of about 11,802 (158)
Abstrak— Perkembangan penduduk dan peningkatan ekonomi masyarakat menjadi salah satu penyebab peningkatan kebutuhan energi listrik. Konsekuensinya, ketersediaan sumber dan prasarana penyaluran energi harus dapat memastikan kualitas catu daya listrik ...
Eko Kuncoro +3 more
doaj +1 more source
Abstract Background The prognostic significance of standardized phase angle (StPhA) and bioelectrical impedance vector analysis (BIVA) remains unclear among hospitalized older individuals. Our study aimed to investigate the prognostic significance of StPhA and BIVA patterns concerning overall survival in hospitalized older patients.
Nahara Oliveira Lima da Silva Diniz +8 more
wiley +1 more source
Dc fault current calculation method in MMC-HVDC grid considering current-limiting devices
This paper proposes a DC fault current calculation method to reveal the fault current evolution mechanism of the modular multilevel converter (MMC)-based HVDC grid.
Jianzhong Xu +3 more
doaj +1 more source
An improved fault current limiter for hybrid DC circuit breakers in large-scale MMC-HVDC systems
Designing multi-terminal HVDC systems presents significant challenges, particularly in control, modeling, and protection. One of the most critical concerns is the protection of these systems from DC short circuits.
Rashid Hussain Chandio +3 more
doaj +1 more source
A Novel Overcurrent Suppression Strategy during Reclosing Process of MMC-HVDC
A modular multilevel converter based high-voltage DC (MMC-HVDC) system has been the most promising topology for HVDC. A reclosing scheme is usually configured because temporary faults often occur on transmission lines especially when overhead lines are ...
Bin Jiang, Yanfeng Gong
doaj +1 more source
Optimizing the sensitivity and speed of the overcurrent protection system in the presence of distributed generation units while also ensuring the cost-effective design of the fault current limiter (FCL) represents great challenges for engineers.
Mahmoud A. Elsadd +4 more
doaj +1 more source
The production of bulk Bi2+xSr3-yCa yCu 2O8+delta (Bi-2212) superconductors for fault current limiter application was developed via a partial-melting route.
Bojan A. Marinkovic +6 more
doaj +1 more source
Design of a multifunction novel flexible fault current limiter for AC distribution network. [PDF]
Liu Y +7 more
europepmc +1 more source
With the continuous development of power grid, the high short-circuit threatens the stability of the power system. The short-circuit exceeds the disconnection capacity of the circuit breaker and has a negative impact on the integrity and stability of the
Duanjiao Li +9 more
doaj +1 more source
Analysis and mitigation of PQ disturbances in grid connected system using fuzzy logic based IUPQC. [PDF]
Ravi T +4 more
europepmc +1 more source

