Results 41 to 50 of about 7,576,309 (147)

Current-limiting characteristics of saturated iron-core fault current limiters in VSC-HVDC systems based on electromagnetic energy conversion mechanism

open access: yesJournal of Modern Power Systems and Clean Energy, 2018
A common method to examine the current-limiting performance of saturated iron-core fault current limiter (SI-FCL) in high-voltage direct-current transmission based on voltage source converter (VSC-HVDC) systems is to solve differential equations based on
Botong LI   +4 more
doaj   +1 more source

DC Current Limiting Characteristics of Flux-Coupled Type SFCL Using Superconducting Element Connected in Parallel in a DC System

open access: yesEnergies, 2021
In this paper, the fault current limiting (FCL) characteristics of a flux-coupled type superconducting fault current limiter (SFCL) with parallel connection between two windings in a DC system were analyzed. The flux-coupled type SFCL was composed of two
Young-Pil Kim, Seok-Cheol Ko
doaj   +1 more source

Fault ride-through enhancement of fixed speed wind turbine using bridge-type fault current limiter

open access: yesJournal of Electrical Systems and Information Technology, 2016
The interaction between wind energy turbines and the grid results in two main problems, increasing the short-circuit level and reducing the Fault Ride-Through (FRT) capability during faults.
Mostafa I. Marei   +2 more
doaj   +1 more source

A current‐limiting DC circuit breaker with power flow control capability

open access: yesIET Generation, Transmission & Distribution, 2022
Power flow controller (PFC), fault current limiter (FCL) and DC circuit breaker (DCCB) are important equipment in the DC grid. There are a large number of power electronic components in these equipment, resulting in high cost.
Shimin Xue   +5 more
doaj   +1 more source

Protection System for LVDC Distribution Networks Using a Fault Current-Limiting Converter and Protection Zones

open access: yesIEEE Access, 2023
In this study, we propose a generalized protection system for low-voltage DC (LVDC) distribution networks based on fault current-limiting (FCL) and the concept of protection zones (PZs).
Jin-Su Kim, Eun-Chul Lee, Sang-Yun Yun
doaj   +1 more source

Reduction Effect of Semiconductor Type Fault Current Limiter on Interrupting Duty of a Circuit Breaker [PDF]

open access: yes, 2002
Calculations were carried out to study the effect of a semiconductor type of fault current limiter (FCL) upon the interrupting duty imposed on a circuit breaker when a fault occurs at a distance of 1 to 8 km downstream from the load side terminals of the
Calixte, Evenson   +4 more
core   +1 more source

An effective fault management scheme and comprehensive double line‐frequency ripple propagation analysis for MVDC networks

open access: yesIET Generation, Transmission & Distribution, 2021
This paper proposes an effective fault management scheme for medium‐voltage direct current (MVDC) networks, which includes a virtual‐impedance‐based fault current limiter (VI‐FCL) on the DC side and a positive‐negative‐sequence (PNS) control scheme on ...
Dongsen Sun   +3 more
doaj   +1 more source

A voltage-clamped bidirectional fault current limiter based on a three-winding coupled inductor for DC power grids

open access: yesInternational Journal of Electrical Power & Energy Systems
The DC fault is a serious challenge to voltage-source-converter-based HVDC (VSC-HVDC) systems, and the fault current limiter (FCL) is one of the key measures to solve the DC fault and reduce the capacity of the DC circuit breaker.
Ziao Yuan   +4 more
doaj   +1 more source

Improved Low Voltage Ride-Through Capability of DFIG with ESO Controller under Unbalanced Network Conditions

open access: yesMajlesi Journal of Electrical Engineering
Under unbalanced grid condition, in a Doubly-Fed Induction Generator (DFIG), voltage, current, and flux of the stator become asymmetric. Therefore, active-reactive power and torque will be oscillating.
Ali Akbar Vali   +2 more
doaj   +1 more source

Model‐Informed Dose Optimization of Anakinra in Preterm Neonates Implications for Safe and Effective Dosing

open access: yesClinical Pharmacology &Therapeutics, EarlyView.
Anakinra, an interleukin‐1 receptor antagonist, shows promise for reducing inflammatory complications of premature birth. However, the pharmacokinetics (PK) of anakinra in neonates has not been characterized, limiting evidence‐based dosing. This study aimed to develop a population PK model for anakinra to guide dosing in preterm neonates.
Jia Li   +27 more
wiley   +1 more source

Home - About - Disclaimer - Privacy