Results 61 to 70 of about 7,576,309 (147)
Placement optimization of Multi-Type fault current limiters based on genetic algorithm
The fault current limiter (FCL) is an effective measure for improving system stability and suppressing short-circuit fault current. Because of space and economic costs, the optimum placement of FCLs is vital in industrial applications. In this study, two
Guofeng Jin +4 more
doaj +1 more source
Control Design for a Power Electronic Based Fault Current Limiter (FCL)
This paper shows a solution for controlling shortcircuit currents of a power electronic based Fault Current Limiter (FCL). A model for control design of three-phase short-circuit currents will be presented. A way of limiting the maximum aperiodic short-circuit current is derived with special regards to the stability of the entire system.
null C. Hahn +2 more
openaire +1 more source
The Y supersaturation in the [Ba‐Cu(I/II)‐O] transient liquid composition is the driving force toward YBCO nucleation and growth in TLAG. Tuning the initial (Ba:Cu) molar ratio in the ink composition determines the YBCO epitaxial nucleation through supersaturation control.
Lavinia Saltarelli +12 more
wiley +1 more source
Power systems under expansion suffer from escalating fault levels that impact equipment integrity, operational flexibility, and the overall security of the system.
Hamood Naji +2 more
doaj +1 more source
ABSTRACT The detection and classification of diseases have become a field of interest for artificial intelligence in recent years, where the development of methods and models that allow support for specialists in different health fields has allowed early detection of diseases and the provision of timely treatment to patients.
Rodrigo Cordero‐Martínez +2 more
wiley +1 more source
Feasibility Study of Superconducting Power Flow Controller and Fault Current Limiter (SPFCL) [PDF]
A superconducting power flow controller and fault current limiter is proposed in this paper, which can not only control power flow in the steady operating state, but also limit fault current in the fault condition.
Okubo, H. +7 more
core +1 more source
A Phase Ib Case Series Using Bortezomib With Chemotherapy in Atypical Teratoid/Rhabdoid Tumors
ABSTRACT Background Atypical teratoid/rhabdoid tumors (ATRTs) are aggressive pediatric brain tumors that are sensitive to proteasome inhibitors in preclinical models. We evaluated the feasibility of combining the proteasome inhibitor, bortezomib, with chemotherapy.
Wan‐Ling Ho +38 more
wiley +1 more source
New Computational Method for Optimal Allocation of Fault Current Limiters in Power Systems
Expansion of power system causes short-circuit currents (SCC) of networks to exceed the tolerable SCCs of equipment. The utilization of fault current limiter (FCL) in such networks is needed to address this issue.
M. Ghotbi-Maleki, R. Mohammadi Chabanloo
doaj
A novel current-limiting hybrid DC breaker based on thyristors
Since the DC current has no zero-crossing in high-voltage and large-capacity DC scenarios, and the low line impedance results in a large growth rate of fault current, the breaking requirements of DC circuit breakers (DCCB) are further increased.
Xinchao Yu +4 more
doaj +1 more source
Redefining Optimal Coverage Path Planning for FLS‐Equipped AUVs With Deep Reinforcement Learning
ABSTRACT Autonomous Underwater Vehicles (AUVs) have emerged as indispensable tools for a variety of subsea tasks, from habitat monitoring and seabed mapping to infrastructure inspection and mine countermeasures. A fundamental challenge in this field is Coverage Path Planning (CPP), the problem of ensuring complete and efficient area coverage.
Lorenzo Cecchi +3 more
wiley +1 more source

