Results 11 to 20 of about 869,116 (286)

Discrimination of Transformer Inrush Currents and Internal Fault Currents Using Extended Kalman Filter Algorithm (EKF)

open access: yesEnergies, 2021
The discrimination of inrush currents and internal fault currents in transformers is an important feature of a transformer protection scheme. The harmonic current restrained feature is used in conventional differential relay protection of transformers. A
Sunil Kumar Gunda   +1 more
doaj   +4 more sources

Thruster Fault Diagnostics and Fault Tolerant Control for Autonomous Underwater Vehicle with Ocean Currents

open access: yesMachines, 2022
Autonomous underwater vehicle (AUV) is one of the most important exploration tools in the ocean underwater environment, whose movement is realized by the underwater thrusters, however, the thruster fault happens frequently in engineering practice.
Qunhong Tian   +3 more
doaj   +4 more sources

Open-Circuit Fault-Tolerant Control of Multi-Phase PM Machines by Compensating the d-q Axes Currents

open access: yesEnergies, 2021
This paper presents a novel method to control sinusoidal distributed winding or sinusoidal back electromotive force (back-EMF) multi-phase permanent magnet (PM) machines under open-circuit fault conditions.
Ali Akay, Paul Lefley
doaj   +2 more sources

Current Only-Based Fault Diagnosis Method for Industrial Robot Control Cables

open access: yesSensors, 2022
With the growth of factory automation, deep learning-based methods have become popular diagnostic tools because they can extract features automatically and diagnose faults under various fault conditions.
Heonkook Kim, Hojin Lee, Sang Woo Kim
doaj   +2 more sources

Real-Time Zero-Sequence-Voltage Estimation and Fault-Tolerant Control for an Open-Winding Five-Phase Fault-Tolerant Fractional-Slot Concentrated-Winding IPM Motor Under Inter-Turn Short-Circuit Fault [PDF]

open access: yesSensors (Basel)
Inter-turn short-circuit (ITSC) faults in motor drives can induce substantial circulating currents and localized thermal stress, ultimately degrading winding insulation and compromising torque stability.
Cui, Ronghua   +7 more
core   +2 more sources

Superconducting fault current limiter application in a power-dense marine electrical system [PDF]

open access: yes, 2011
Power-dense, low-voltage marine electrical systems have the potential for extremely high fault currents. Superconducting fault current limiters (SFCLs) have been of interest for many years and offer an effective method for reducing fault currents.
Burt, Graeme   +5 more
core   +4 more sources

Investigation of superconducting fault current limiter application in a power-dense marine electrical network [PDF]

open access: yes, 2010
Power-dense, low-voltage marine electrical systems have the potential for extremely high fault currents. Limitation of fault currents is very attractive in a marine vessel, particularly in terms of switchgear cost, size, and weight, and reducing damage ...
Blair, S.M.   +11 more
core   +4 more sources

Operational control and protection implications of fault current limitation in distribution networks [PDF]

open access: yes, 2009
Rising short-circuit fault current levels is one of the problems associated with the increased presence of distributed generation (DG) in electrical networks.
Blair, S.M.   +3 more
core   +3 more sources

Discrimination between inrush and fault currents of transformers using Artificial Neural Network Tools [PDF]

open access: yesThe Egyptian International Journal of Engineering Sciences and Technology, 2022
This paper presents a technique for modeling of transformer inrush and fault currents using fitting tools of artificial neural network (ANN) as a type of new security techniques. Inrush and fault currents at different winding connection, initial flux and
Maha Goda
doaj   +1 more source

Analysis of the Possibilities of Selective Detection of a Single Line-to-Ground Fault in a Medium Voltage Network with Isolated Neutral

open access: yesEnergies, 2021
The paper analyses how the characteristics of the medium-voltage network with insulated neutral and the conditions under which the single line-to-ground fault occurs (insulation condition and value of the fault resistance) influence the zero-sequence ...
Dumitru Toader   +4 more
doaj   +1 more source