Results 41 to 50 of about 23,927 (265)
With the rapid development of high‐speed railway, the auto‐transformer traction network (ATN) is also expanding. However, due to the improved performance of electric multiple units (EMUs) and the non‐linear relationship between impedance and ground fault
Shuai Wang +4 more
doaj +1 more source
Enteropathogenic E. coli (EPEC) infects the human intestinal epithelium, resulting in severe illness and diarrhoea. In this study, we compared the infection of cancer‐derived cell lines with human organoid‐derived models of the small intestine. We observed a delayed in attachment, inflammation and cell death on primary cells, indicating that host ...
Mastura Neyazi +5 more
wiley +1 more source
Fault recognition method of smart grid data acquisition system based on FNN and sequential DS fusion
It is of significant practical importance to ensure the operational safety of the smart grid, which requires real‐time fault diagnosis and identifying what causes it based on an enormous amount of data.
Hanzhe Qiao +7 more
doaj +1 more source
Aiming at the problem of fault diagnosis in continuous time systems, a kind of fault diagnosis algorithm based on adaptive nonlinear proportional integral (PI) observer, which can realize the effective fault identification, is studied in this paper ...
Qing Miao +3 more
doaj +1 more source
Bifidobacterium bifidum establishes symbiosis with infants by metabolizing lacto‐N‐biose I (LNB) from human milk oligosaccharides (HMOs). The extracellular multidomain enzyme LnbB drives this process, releasing LNB via its catalytic glycoside hydrolase family 20 (GH20) lacto‐N‐biosidase domain.
Xinzhe Zhang +5 more
wiley +1 more source
Crosstalk between the ribosome quality control‐associated E3 ubiquitin ligases LTN1 and RNF10
Loss of the E3 ligase LTN1, the ubiquitin‐like modifier UFM1, or the deubiquitinating enzyme UFSP2 disrupts endoplasmic reticulum–ribosome quality control (ER‐RQC), a pathway that removes stalled ribosomes and faulty proteins. This disruption may trigger a compensatory response to ER‐RQC defects, including increased expression of the E3 ligase RNF10 ...
Yuxi Huang +8 more
wiley +1 more source
When a single line-to-ground fault occurs in the ungrounded distribution system, the steady-state fault current is relatively small for fault analysis and the transient fault current is observable, which can be used for faulted feeder identification and ...
Ling Liu
doaj +1 more source
Peptide‐based ligand antagonists block a Vibrio cholerae adhesin
The structure of a peptide‐binding domain of the Vibrio cholerae adhesin FrhA was solved by X‐ray crystallography, revealing how the inhibitory peptide AGYTD binds tightly at its Ca2+‐coordinated pocket. Structure‐guided design incorporating D‐amino acids enhanced binding affinity, providing a foundation for developing anti‐adhesion therapeutics ...
Mingyu Wang +9 more
wiley +1 more source
Aiming at the problems of fault perception and identification in high resistance grounding fault of distribution network, a high resistance grounding fault perception method for parameter-asymmetric distribution network based on damping rate variation is
Penghui YANG +5 more
doaj +1 more source
The role of histone modifications in transcription regulation upon DNA damage
This review discusses the critical role of histone modifications in regulating gene expression during the DNA damage response (DDR). By modulating chromatin structure and recruiting repair factors, these post‐translational modifications fine‐tune transcriptional programmes to maintain genomic stability.
Angelina Job Kolady, Siyao Wang