Results 111 to 120 of about 27,775 (166)
Some of the next articles are maybe not open access.
1991, Proceedings. International Test Conference, 2005
A two-stage procedure for locating VLSI faults is presented. The approach utilizes dynamic fault dictionaries, test set partitioning, and reduced fault lists to achieve a reduction in size and complexity over classic static fault dictionaries. An industrial implementation is reported in which faults were injected and diagnosed in a VLSI chip and the ...
Paul G. Ryan +2 more
openaire +1 more source
A two-stage procedure for locating VLSI faults is presented. The approach utilizes dynamic fault dictionaries, test set partitioning, and reduced fault lists to achieve a reduction in size and complexity over classic static fault dictionaries. An industrial implementation is reported in which faults were injected and diagnosed in a VLSI chip and the ...
Paul G. Ryan +2 more
openaire +1 more source
A Fault Locator For Integrated Optics
Optical Fiber Sensors, 1992Power of resolution of a fault locator has been improving by leaps and bounds. The best values reported so far are of an order of millimeters and the locators are primarily used for finding faults in the bulk media such as breaks in an optical fiber.
K. Iizuka, S. Fujii
openaire +1 more source
A two stage fault location algorithm for locating faults on transmission lines
2013 International Conference on Computation of Power, Energy, Information and Communication (ICCPEIC), 2013A continuous and reliable electrical energy supply is the objective of any power system operation. Electricity is the driving force behind industry and subsequently economy. There are various types of faults appear in power system. Faults can appear due to bad weather conditions, equipment damage, equipment failure, environment changes and many other ...
G. Dineshkumar, S. Thangavel
openaire +1 more source
Construction of a fault location algorithm
Automatica, 1996zbMATH Open Web Interface contents unavailable due to conflicting licenses.
openaire +2 more sources
Fault Location with Current Monitoring
1991, Proceedings. International Test Conference, 2005Recently there has been renewed interest in fault detection in static CMOS circuits through current monitoring (“Iddq testing”). It is shown that accurate defect (diagnosis miay be performed with a combination of current and voltage observations. The proposed system combines a simple single fault model for test generation with a more realistic multiple
openaire +2 more sources
Electrical Engineering, 1948
The inspection of circuits by pulse reflection methods is well known to communications engineers. In particular this technique has been used in inspecting high-frequency coaxial telephone and television lines. The “Linascope” is an electronic instrument for locating faults on open-wire telephone and transmission lines. The unit generates repetitively a
J. R. Leslie, K. H. Kidd
openaire +1 more source
The inspection of circuits by pulse reflection methods is well known to communications engineers. In particular this technique has been used in inspecting high-frequency coaxial telephone and television lines. The “Linascope” is an electronic instrument for locating faults on open-wire telephone and transmission lines. The unit generates repetitively a
J. R. Leslie, K. H. Kidd
openaire +1 more source
2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability, 2007
A continuous and reliable electrical energy supply is the objective of any power system operation. However, faults inevitably occur in power system due to bad weather conditions, equipment damage, equipment failure, environment changes, human or animal interference and many other reasons.
Mladen Kezunovic +3 more
openaire +1 more source
A continuous and reliable electrical energy supply is the objective of any power system operation. However, faults inevitably occur in power system due to bad weather conditions, equipment damage, equipment failure, environment changes, human or animal interference and many other reasons.
Mladen Kezunovic +3 more
openaire +1 more source
Thermal testing: fault location strategies
Proceedings 18th IEEE VLSI Test Symposium, 2002By measuring the temperature at some points of an IC during a test procedure, defects can be detected (fault testing). With a simple processing of the measured temperature waveform, the distance between the temperature monitoring point and the activated defect can be derived.
Josep Altet +4 more
openaire +1 more source
Electronics Education, 1991
Our computer department had a problem with its Nimbus network and they approached me with the suggestion that it would be a difficult technical problem to locate a suspected fault in the cable system. I felt instinctively optimistic, recalling the classic physics experiment in which pulses are sent down a cable of measured length and their times of ...
openaire +1 more source
Our computer department had a problem with its Nimbus network and they approached me with the suggestion that it would be a difficult technical problem to locate a suspected fault in the cable system. I felt instinctively optimistic, recalling the classic physics experiment in which pulses are sent down a cable of measured length and their times of ...
openaire +1 more source
Optical fiber fault location method
Applied Optics, 1976An optical pulse reflection method based on the optical radar principle is discussed for optical fiber cable fault location. The optical reflection coefficient at flat surfaces of optical fibers was measured and found to be in good agreement with calculated value.
Y, Ueno, M, Shimizu
openaire +2 more sources