Results 241 to 250 of about 445,363 (308)
Efficient data consensus algorithm integrating FL and blockchain dynamic partition protocol PBFT. [PDF]
Huang G.
europepmc +1 more source
No fault vaccine injury compensation after COVID-19: A systematic literature review and proposed typology. [PDF]
Halabi S +6 more
europepmc +1 more source
Enhancing reliability in electrical grids: A hybrid machine learning approach for electrical faults classification. [PDF]
Begum M +6 more
europepmc +1 more source
Smart technique for calculating fault current model parameters using short circuit current measurements. [PDF]
Mahmoud RA, Malik OP, Fayek WM.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Transformer fault protection for low impedance faults
Conference Record of the Twenty-Third International Power Modulator Symposium (Cat. No. 98CH36133), 2002Precision measurements of transformer insulation quality demands minimizing damage during test-to-breakdown. A fault tolerant insertion system has been developed for this application. This paper addresses a current limiting model for this system design that protects the high current insertion transformer from sustaining irreparable damage.
T.R. Eckstein +3 more
openaire +1 more source
Earth fault distance protection
IET Conference Publications, 2009Earth fault distance protection with distance protection relays is common practice in solidly grounded networks. However, in compensated networks earth faults can cause big problems, because they do not extinguish themselves. To find the fault point is from high interest also in combination with network expansion. In previous investigations the authors
G. Achleitner +3 more
openaire +1 more source
Preventive arc fault protection
2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294), 2002An arc fault in switchgear is a failure with enormous effects and a high hazard potential to persons in its vicinity. Therefore the switchgear manufacturers intensively look for possibilities to minimize this hazard potential. The ways used in industrial practice can be separated in to two basic directions, the active and the passive protection.
openaire +1 more source
The arc-fault circuit protection
Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248), 2002In electrical power systems bolted short-circuits are rare and the fault usually involves arcing and burning; mostly the limit value of minimum short-circuit depends on arcing-fault. In AC low voltage systems, the paper examines the arcing-fault branch circuits as weak points. Different protection measures are available against the arc-faults.
PARISE, Giuseppe +3 more
openaire +2 more sources
2010
This chapter describes symmetrical three phase faults (Section 13.1), breakers (Section 13.2) and relays (Section 13.3). The chapter also describes measurement devices of non-standard quantities during time domain simulations, namely the Phasor Measurement Unit (Section 13.4) and the bus frequency measurement (Section 13.5).
openaire +1 more source
This chapter describes symmetrical three phase faults (Section 13.1), breakers (Section 13.2) and relays (Section 13.3). The chapter also describes measurement devices of non-standard quantities during time domain simulations, namely the Phasor Measurement Unit (Section 13.4) and the bus frequency measurement (Section 13.5).
openaire +1 more source